Activating enables
To activate the enables, proceed as follows:
1. Click the Set/remove enables
button to enable the axis.
The LEDs indicate the status of the enables.
Specifying motion commands for axis
1. Specify motion commands for the axis.
The following functions are available:
Button Meaning/function
Speed default
This command specifies that the axis is started speed-controlled.
Specify a speed setpoint to which the axis can be ramped up via a velocity profile.
The command is possible for all axis types; position and following axes are operated speed-controlled.
Start axis position-controlled
This command specifies that the axis is started position-controlled.
Specify a speed setpoint to which the axis can be ramped up via a velocity profile.
The command is possible for position and following axes.
Position axis
With this command, you specify positioning of the axis (positioning or synchronous axis) at a specific position.
The position value entered can be absolute or relative. Modulo axes can also be positioned via the shortest path.
The programmed position must be within the software limit switches.
Home axis
With an absolute measuring system, homing is only required once during commissioning. When this is completed,
the position value will be known when the machine is switched on.
In the case of an incremental measuring system, the machine must be homed every time it is switched on.
Start axis motion
To start the axis motion, proceed as follows:
1. Click the
switch to start the motion command parameterized last.
Or click the switch to start the Speed specification or Start axis position-controlled motion
commands in jog mode.
The motion continues as long as the right-hand mouse button is pressed.
Exit axis control panel
To exit the axis control panel, proceed as follows:
1. To stop the system, click the
switch.
2. Deactivate the Set/remove enables button
. Confirm the Disable axis dialog with OK.
Note
If you want to traverse the axis again, acknowledge all alarms in the "Alarms" window.
Configuring/parameterizing
6.5 Creating and testing an axis
SIMOTION SCOUT
Configuration Manual, 11/2016
109
Содержание SIMOTION SCOUT
Страница 12: ...Preface 1 4 Hotline and Internet addresses SIMOTION SCOUT 12 Configuration Manual 11 2016 ...
Страница 32: ...Installation 4 4 Licenses SIMOTION SCOUT 32 Configuration Manual 11 2016 ...
Страница 64: ...User interface 5 11 Adding add ons to the workbench SIMOTION SCOUT 64 Configuration Manual 11 2016 ...
Страница 146: ...Configuring parameterizing 6 14 Writing the boot sector SIMOTION SCOUT 146 Configuration Manual 11 2016 ...
Страница 224: ...Product combinations 13 9 DCC programming system SIMOTION SCOUT 224 Configuration Manual 11 2016 ...
Страница 244: ...Index SIMOTION SCOUT 244 Configuration Manual 11 2016 ...