![Siemens SIMOCODE pro Скачать руководство пользователя страница 274](http://html.mh-extra.com/html/siemens/simocode-pro/simocode-pro_programming-and-operating-manual_1265395274.webp)
Parameter
A.7 Block parameter MMRevDhl
SIMOCODE pro PCS 7 Library V9.0
274
Programming and Operating Manual, 06/2017, A5E40899442002A/RS-AA/001
Parameter
Data format
Default setting
Meaning
LocalLi
STRUCT
•
Value: BOOL
•
ST: BYTE
–
•
0
•
16#80
1 = Local Mode: Local Operation by Field Signal
LocalOp
BOOL
FALSE
1 = Local Mode: Local Operation by Operator
MS_RelOp
BOOL
FALSE
Operator input for MS Release, 1: MS release require-
ment
OosOp
BOOL
FALSE
1 = Oos Mode: Oos Mode by Operator
OosLi
STRUCT
•
Value: BOOL
•
ST: BYTE
–
•
0
•
16#80
1 = Oos Mode: Oos Mode by Field Signal
FFwdLocal
STRUCT
•
Value: BOOL
•
ST: BYTE
–
•
0
•
16#80
1 = Start Local: Field Fast Forward Start Signal
FwdLocal
STRUCT
•
Value: BOOL
•
ST: BYTE
–
•
0
•
16#80
1 = Start Local: Field Forward Start Signal
StopLocal
STRUCT
•
Value: BOOL
•
ST: BYTE
–
•
0
•
16#80
1 = Stop Local: Field Stop Signal
RevLocal
STRUCT
•
Value: BOOL
•
ST: BYTE
–
•
0
•
16#80
1 = Start Local: Field Reverse Start Signal
FRevLocal
STRUCT
•
Value: BOOL
•
ST: BYTE
–
•
0
•
16#80
1 = Start Local: Field Fast Reverse Start Signal
LocalSetting
INT
0
Local Mode Behavior
FbkFFwd
STRUCT
•
Value: BOOL
•
ST: BYTE
–
•
0
•
16#80
Feedback of Control Fast Forward:
0 = Stop
1 = Run
FbkFwd
STRUCT
•
Value: BOOL
•
ST: BYTE
–
•
0
•
16#80
Feedback of Control Forward:
0 = Stop
1 = Run
FbkRev
STRUCT
•
Value: BOOL
•
ST: BYTE
–
•
0
•
16#80
Feedback of Control Reverse:
0 = Stop
1 = Run
FbkFRev
STRUCT
•
Value: BOOL
•
ST: BYTE
–
•
0
•
16#80
Feedback of Control Fast Reverse:
0 = Stop
1 = Run