Description
● Severity Filters
You can filter the entries in the table according to severity. To display all the entries, enable
or disable all parameters.
Note
For each severity, a maximum of 400 entries in the table are possible. If the maximum
number of entries is reached for a severity, the oldest entries of this severity are overwritten
in the table. The table remains permanently in the memory.
– Critical
Critical
When this parameter is enabled, all entries of the category "Critical" are displayed.
– Warning
warning
When this parameter is enabled, all entries of the category "Warning" are displayed.
– Info
Informative
When this parameter is enabled, all entries of the category "Info" are displayed.
The table has the following columns:
● Restart
Counts the number of restarts since you last reset to factory settings and shows the device
restart after which the corresponding event occurred.
● System Up Time
Shows the time the device has been running since the last restart when the described event
occurred.
● System Time
Shows the date and time when the described event occurred. If no system time is set, the
box displays "Date/time not set".
● Severity
Sorts the entry into the categories above.
● Log Message
Displays a brief description of the event that has occurred.
Configuring with Web Based Management
4.4 "Information" menu
SCALANCE S615 Web Based Management
90
Configuration Manual, 11/2019, C79000-G8976-C388-08
Содержание SIMATIC NET SCALANCE S615
Страница 12: ...Table of contents SCALANCE S615 Web Based Management 12 Configuration Manual 11 2019 C79000 G8976 C388 08 ...
Страница 24: ...Description 1 7 PLUG SCALANCE S615 Web Based Management 24 Configuration Manual 11 2019 C79000 G8976 C388 08 ...
Страница 316: ...Appendix A A 3 Syslog messages SCALANCE S615 Web Based Management 316 Configuration Manual 11 2019 C79000 G8976 C388 08 ...
Страница 320: ...Index SCALANCE S615 Web Based Management 320 Configuration Manual 11 2019 C79000 G8976 C388 08 ...