– Mobile data usage (only with M87x)
This event occurs when 75% or 100% of the defined data volume has been reached, see
"Interfaces > Mobile > General".
– Connection Check
This event occurs when connections are being monitored, see "System > Connection
Check".
The device sends an e-mail. This is only possible if the SMTP server is set up and the
"SMTP client" function is enabled.
● Trap
The device sends an SNMP trap. This is only possible if "SNMPv1 Traps" is enabled in
"System > Configuration".
● Log Table
The device writes an entry in the event log table, see "Information > Log Table"
● Syslog
The device writes an entry to the system log server. This is only possible if the system log
server is set up and the "Syslog client" function is enabled.
● Faults
The device triggers an error. The error LED lights up and the currently pending error is
displayed under "Information > Faults".
● SMS (only with M87x)
The device sends an SMS. This is only possible if "System > SMS > Event SMS" is enabled
and the telephone number of the recipient is configured.
● Digital Out
Controls the digital output or signals the status change with the "DO" LED.
The digital output is closed by default. The digital output is opened when you activate at least
one event for the digital output. It also is no longer automatically connected to the fault LED.
You connect the digital output with the fault LED under "Fault State Change".
● VPN Tunnel
Controls the forwarding of an event to a VPN connection (IPsec, OpenVPN, SINEMA RC).
As long as the event is present, the VPN connection is switched to active.
● Firewall
Controls application of the user-defined rule set. This requires a rule set to be assigned to
the digital input under "Security > Firewall > ".
● Cloud Connector
Controls the forwarding of an event to the TIA Portal Cloud Connector communication. The
communication connection is active as long as the event is present.
Configuring with Web Based Management
4.5 "System" menu
SCALANCE S615 Web Based Management
140
Configuration Manual, 11/2019, C79000-G8976-C388-08
Содержание SIMATIC NET SCALANCE S615
Страница 12: ...Table of contents SCALANCE S615 Web Based Management 12 Configuration Manual 11 2019 C79000 G8976 C388 08 ...
Страница 24: ...Description 1 7 PLUG SCALANCE S615 Web Based Management 24 Configuration Manual 11 2019 C79000 G8976 C388 08 ...
Страница 316: ...Appendix A A 3 Syslog messages SCALANCE S615 Web Based Management 316 Configuration Manual 11 2019 C79000 G8976 C388 08 ...
Страница 320: ...Index SCALANCE S615 Web Based Management 320 Configuration Manual 11 2019 C79000 G8976 C388 08 ...