Table 2 has the following columns:
● Event
The "Event" column contains the following:
– Cold/Warm Start
The device was turned on or restarted by the user. In the error memory of the device a
new entry is generated with the type of restart performed.
– Link Change
This event occurs only when the port status is monitored and has changed, see "System
> Fault Monitoring > Link Change".
– Authentication Failure
This event occurs when access is attempted with an incorrect password.
– Fault State Change
The fault status has changed. The fault status can relate to the activated port monitoring,
the response of the digital output or the power supply monitoring.
For an fault to also be signaled by the fault LED "F", you must enable "Fault State
Change" for the "Digital Out". In this case, the fault LED "F" lights up when an internal
error occurs and the digital input is closed.
– Security Logs
An entry is made in the security log if the IPsec method was used for VPN.
– Firewall Logs
Each time individual firewall rules are applied, this is recorded in the firewall log. To do
this, the LOG function must be enabled for the various firewall functions.
– DDNS Client Logs
The event occurs when the DDNS client synchronizes the assigned IP address with the
hostname registered at the DDNS provider.
– System General Logs
Connection establishment, change to the configuration.
– System Connection Status
The connection status has changed.
– Digital In
The event occurs when the status of the digital input has changed.
– VPN Tunnel
The event occurs when the status of VPN (IPsec, OpenVPN, SINEMA RC) has changed.
– Secure NTP
This event occurs when the device receives the system time from a secure NTP server.
– Cloud Connector (only with M804PB)
This event occurs when the operating state of the Cloud Connector has changed.
– Configuration Change
This event occurs when the configuration of the device has changed.
– Service Information
For certain events, entries are made in the log table even without configuration. For
these events, you can configure additional subsequent actions here (e-mail, trap,
syslog).
Configuring with Web Based Management
4.5 "System" menu
SCALANCE S615 Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C388-08
139
Содержание SIMATIC NET SCALANCE S615
Страница 12: ...Table of contents SCALANCE S615 Web Based Management 12 Configuration Manual 11 2019 C79000 G8976 C388 08 ...
Страница 24: ...Description 1 7 PLUG SCALANCE S615 Web Based Management 24 Configuration Manual 11 2019 C79000 G8976 C388 08 ...
Страница 316: ...Appendix A A 3 Syslog messages SCALANCE S615 Web Based Management 316 Configuration Manual 11 2019 C79000 G8976 C388 08 ...
Страница 320: ...Index SCALANCE S615 Web Based Management 320 Configuration Manual 11 2019 C79000 G8976 C388 08 ...