4.5.4.2
HTTP
Loading and saving data via HTTP
The WBM allows you to store device data in an external file on your client PC or to load such
data from an external file from the PC to the devices. This means, for example, that you can also
load new firmware from a file located on your Admin PC. On this page, the certificates required
to establish a secure VPN connection can also be loaded.
Firmware
The firmware is signed and encrypted. This ensures that only firmware created by Siemens can
be downloaded to the device.
Configuration files
Note
Configuration files and Trial mode/Automatic Save
In "Automatic Save" mode, the data is saved automatically before the configuration files
(ConfigPack and Config) are transferred.
In "Trial" mode, although the changes are adopted, they are not saved in the configuration files
(ConfigPack and Config). Use the "Write Startup Config" button on the "System >
Configuration" WBM page to save changes in the configuration files.
CLI script file
You can download existing CLI configurations (RunningCLI) and upload your own CLI scripts
(Script).
Note
The downloadable CLI script is not intended to be uploaded again unchanged.
CLI commands for saving and loading files cannot be executed with the CLI script file (Script).
Exchange of configuration data with STEP 7 Basic/Professional using a file
You use the two file types "RunningSINEMAConfig" and "SINEMAConfig" to exchange
configuration data between a device (WBM) and STEP 7 Basic/Professional via a file.
Requirements:
● Same article number
● Same firmware version
● Password
You assign the password in the WBM under "System > Load&Save > Passwords".
Configuring with Web Based Management
4.5 "System" menu
SCALANCE S615 Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C388-08
125
Содержание SIMATIC NET SCALANCE S615
Страница 12: ...Table of contents SCALANCE S615 Web Based Management 12 Configuration Manual 11 2019 C79000 G8976 C388 08 ...
Страница 24: ...Description 1 7 PLUG SCALANCE S615 Web Based Management 24 Configuration Manual 11 2019 C79000 G8976 C388 08 ...
Страница 316: ...Appendix A A 3 Syslog messages SCALANCE S615 Web Based Management 316 Configuration Manual 11 2019 C79000 G8976 C388 08 ...
Страница 320: ...Index SCALANCE S615 Web Based Management 320 Configuration Manual 11 2019 C79000 G8976 C388 08 ...