4.5.8.1
Manual Setting
Manual setting of the system time
On this page, you set the date and time of the system yourself. For this setting to be used,
enable "Time Manually".
Description
The page contains the following boxes:
● Time Manually
Enable or disable the manual time setting. If you enable the option, the "System Time" input
box can be edited.
● System Time
Enter the date and time in the format "MM/DD/YYYY HH:MM:SS".
After a restart, the time of day begins at 01/01/2000 00:00:00
● Use PC Time
Click the button to use the time setting of the PC.
● Last Synchronization Time
Shows when the last time-of-day synchronization took place. If no time-of-day
synchronization was possible, the box displays "Date/time not set".
Configuring with Web Based Management
4.5 "System" menu
SCALANCE S615 Web Based Management
156
Configuration Manual, 11/2019, C79000-G8976-C388-08
Содержание SIMATIC NET SCALANCE S615
Страница 12: ...Table of contents SCALANCE S615 Web Based Management 12 Configuration Manual 11 2019 C79000 G8976 C388 08 ...
Страница 24: ...Description 1 7 PLUG SCALANCE S615 Web Based Management 24 Configuration Manual 11 2019 C79000 G8976 C388 08 ...
Страница 316: ...Appendix A A 3 Syslog messages SCALANCE S615 Web Based Management 316 Configuration Manual 11 2019 C79000 G8976 C388 08 ...