You will find further information on this in the device-specific operating instructions.
Configuration
In the factory settings, the SCALANCE S615 can be reached as follows for initial configuration:
Default values set in the factory
Ethernet interface for the configu‐
ration
(internal)
P1 ... P4 (vlan 1)
Ethernet interface for the connec‐
tion to WAN
(external)
P5 (vlan 2)
IP address
192.168.1.1
Subnet mask
255.255.255.0
WBM
Access using HTTPS: TCP port 443
CLI
Access using SSH, TCP port 22
User name
admin
The user name can be changed after the first logon or after a "Re‐
store Factory Defaults and Restart". Afterwards, renaming "admin"
is no longer possible.
Password
admin
The password needs to be changed after the first logon or after a
"Restore Factory Defaults and Restart"
You will find more information in "Web Based Management (Page 61)" and in "Starting and
1.3.1
Use in a PROFINET environment
Note
Validity of CCA declaration
The CCA declaration applies to PROFINET RT without the use in media redundancy structures.
Configuration information
When using the device in a PROFINET environment, follow the following configuration
instructions:
● Set the "Aging Time" to 45 seconds.
● Disable Spanning Tree and enable Passive Listening.
Description
1.3 Requirements for operation
SCALANCE S615 Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C388-08
17
Содержание SIMATIC NET SCALANCE S615
Страница 12: ...Table of contents SCALANCE S615 Web Based Management 12 Configuration Manual 11 2019 C79000 G8976 C388 08 ...
Страница 24: ...Description 1 7 PLUG SCALANCE S615 Web Based Management 24 Configuration Manual 11 2019 C79000 G8976 C388 08 ...
Страница 316: ...Appendix A A 3 Syslog messages SCALANCE S615 Web Based Management 316 Configuration Manual 11 2019 C79000 G8976 C388 08 ...
Страница 320: ...Index SCALANCE S615 Web Based Management 320 Configuration Manual 11 2019 C79000 G8976 C388 08 ...