Simatic 505 SoftShop
7 - Documentation
••••
133
Figure 7.2
Network Header
505 SoftShop provides a simple way to document networks while you
are creating or editing your logic program. The maximum number of
characters you can enter for each header is 16K. The network header is
tied to the corresponding network output. If a XCALL, PGSTS OR
PGTSZ are the outputs, the header is tied to the first occurrence of an X,
Y or C address.
Double-click the Network Header Input icon in the active logic program
window (see Figure 7.1). The Network Header Input dialog box is
displayed (see Figure 7.3). The drop down box paging preference in the
top left-hand corner of the header input box. Controls the page print out
of the particular network header and ladder that is selected. If Page None
is selected there will be no page break between the current network and
last network printed. Page Odd prints the current selected network on the
next odd page. Page Before prints the current selected network on the
next blank page. Type in your header. Select OK when you're finished.
To see network headers in the active logic program, select Program
Setup from the Options menu. Select the Logic tab. Then General from
the drop down box and check Show All Headers.
Figure 7.3