Table 7-8
Electrical data: Overcurrent protection
Device version
(power supply)
Overcurrent protection of the power supply
Non-replaceable fuse
1 x 24 to 48 VDC
1 x T2H / 250 V
2 x 24 to 48 VDC
2 x T2H / 250 V
1 x 100 to 240 VAC / 60 to 250 VDC
1 x T2H / 250 V (AC)
1 x T2H / 300 V (DC)
2 x 100 to 240 VAC / 60 to 250 VDC
2 x T2H / 250 V (AC)
2 x T2H / 300 V (DC)
Table 7-9
Electrical data: Signaling contact
Device version
(power supply)
Voltage via signaling con‐
tact
Switching capacity
(resistive load)
Resistor between
F1-F2
24 to 48 VDC
24 VDC
max. 0.1 A
< 8 Ω
100 to 240 VAC / 60 to
250 VDC
240 VAC
max. 5 A
60 VDC
max. 0.4 A
125 VDC
max. 0.22 A
250 VDC
max. 0.11 A
Table 7-10
Plug-in terminal block for connectors of the power supply and signaling contact
Device version
(power supply)
Power supply
Signaling contact
1 x 24 to 48 VDC
1 x 4-pin
1 x 2-pin
2 x 24 to 48 VDC
2 x 4-pin
2 x 2-pin
1 x 100 to 240 VAC / 60 to
250 VDC
1 x 3-pin
1 x 3-pin
2 x 100 to 240 VAC / 60 to
250 VDC
2 x 3-pin
2 x 3-pin
Table 7-11
Overvoltage category
General
Overvoltage category II
In the application range of EN 60255-27
Overvoltage category III
Technical data
7.2 Connectors and electrical data
SCALANCE XR-300M EEC
60
Compact Operating Instructions, 11/2019, A5E02661176-14
Содержание SCALANCE XR324-4M EEC
Страница 10: ...Introduction SCALANCE XR 300M EEC 10 Compact Operating Instructions 11 2019 A5E02661176 14 ...
Страница 12: ...Safety notes SCALANCE XR 300M EEC 12 Compact Operating Instructions 11 2019 A5E02661176 14 ...
Страница 84: ...Index SCALANCE XR 300M EEC 84 Compact Operating Instructions 11 2019 A5E02661176 14 ...