Principle
The data remains stored on the C-PLUG even when power is turned off. In terms of using the
C-PLUG, there are two ways of operating the device:
● With unwritten C-PLUG
If an empty C-PLUG (factory settings or deleted with the Clean function) is inserted, all the
configuration data of the device is saved to it automatically when the device starts up.
Changes to the configuration during operation are saved without operator intervention on
the C-PLUG if this is in the "ACCEPTED" status. This depends on how you configured your
SCALANCE device. In this mode, the internal memory is neither read nor written. This mode
is active when a C-PLUG is inserted.
● With written C-PLUG
A device with an accepted C-PLUG inserted uses the configuration data of the C-PLUG
automatically when it starts up. Acceptance is possible only when the data was written by
a compatible device type.
Response to errors
Inserting a C-PLUG that does not contain the configuration of a compatible device type,
accidentally removing the C-PLUG or general malfunctions of the C-PLUG are signaled by the
diagnostics mechanisms of the device (LEDs, Web-based management, SNMP, CLI and
PROFINET diagnostics).
4.5.2
Removal and insertion of the C-PLUG (rack devices)
NOTICE
A C-PLUG may only be removed or inserted when the device is turned off.
Position of the C-PLUG with rack devices
With rack devices, the slot is below a cover on the right-hand side of the
housing. After undoing the screw (screw head Torx T10), the cover
plate can be removed and the slot is accessible.
Device description
4.5 C-PLUG
SCALANCE XR-300M EEC
Compact Operating Instructions, 11/2019, A5E02661176-14
27
Содержание SCALANCE XR324-4M EEC
Страница 10: ...Introduction SCALANCE XR 300M EEC 10 Compact Operating Instructions 11 2019 A5E02661176 14 ...
Страница 12: ...Safety notes SCALANCE XR 300M EEC 12 Compact Operating Instructions 11 2019 A5E02661176 14 ...
Страница 84: ...Index SCALANCE XR 300M EEC 84 Compact Operating Instructions 11 2019 A5E02661176 14 ...