Technical data
7
7.1
Construction, installation and environmental conditions
Table 7-1
Construction
Device
Device version
(power supply)
Dimensions (W x H x
D)
Weight
Degree of
protection
XR324-4M
EEC
1 x 24 to 48 VDC
483 × 44 × 305 mm
6500 g
IP20
2 x 24 to 48 VDC
483 × 44 × 305 mm
6800 g
IP20
1 x 100 to 240 VAC / 60 to 250 VDC 483 × 44 × 305 mm
6600 g
IP20
2 x 100 to 240 VAC / 60 to 250 VDC 483 × 44 × 305 mm
7000 g
IP20
Table 7-2
Installation options
Device
Installation options
XR324-4M EEC
19" rack
1)
1)
Note: If mechanical load is high, the device should be secured at four points. You will find more
detailed information in the section "Mechanical load in operation".
Table 7-3
Permitted ambient conditions
Storage/transport temperature
-40 °C to +85 ℃
Max. relative humidity in operation at 25 °C
<= 95% (no condensation)
Max. ambient temperature at operating altitude
2000 m or above:
-5 °C of the max. operating temperature
1)
3000 m or above:
-10 °C of the max. operating temperature
1)
1)
See table: "Operating temperature depending on the media modules used"
Table 7-4
Operating temperature depending on the media modules used
Media module
1)
Installation di‐
rection
Operating temperature
2)
Without media module
Horizontal
-40 °C to +70 °C
Vertical
-40 °C to +50 ℃
SCALANCE XR-300M EEC
Compact Operating Instructions, 11/2019, A5E02661176-14