background image

SIMATIC

Process Control System PCS 7

PCS 7 - PC Configuration (V8.2)

Installation Manual

Valid for PCS 7 as of V8.2

 

03/2016

A5E36200050-AB

Security information

1

Preface

2

PC components of a PCS 7 

system

3

Hardware for PC stations

4

Installing PC stations

5

Appendices

6

Содержание PCS 7

Страница 1: ...CS 7 PCS 7 PC Configuration V8 2 Installation Manual Valid for PCS 7 as of V8 2 03 2016 A5E36200050 AB Security information 1 Preface 2 PC components of a PCS 7 system 3 Hardware for PC stations 4 Installing PC stations 5 Appendices 6 ...

Страница 2: ...l are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufacturers are us...

Страница 3: ... reporting system 27 3 6 5 1 Process Historian and Information Server 27 3 6 5 2 Long term archiving with the Process Historian and Information Server 29 3 7 Solutions for single station systems 29 3 7 1 OS single station system 29 3 7 2 BATCH single station system 32 3 7 3 Route Control single station system 33 3 7 4 Maintenance station single station system 34 3 7 5 SIMATIC PCS 7 BOX stations 35...

Страница 4: ... 7 software 77 5 4 4 How to prepare the engineering station for multi user operation 80 5 4 5 How to install the Process Historian 81 5 4 6 Configuring redundancy for redundant servers 81 5 4 7 Installing a PC for Web Option for OS 82 5 4 8 Setting up user groups and users 82 5 4 9 Installing PCS 7 libraries of older PCS 7 versions 86 5 4 10 How to set permissions for the project paths 86 5 4 11 F...

Страница 5: ...ion to the PC stations 127 5 8 Notes on add ons and utilities 128 5 8 1 Overview of additional programs and utilities for PCS 7 128 5 8 2 Remote diagnostics functions 128 5 8 3 Automatic logon to the operating system 130 5 8 4 Virus scanners 131 5 8 5 Burner software 131 5 8 6 DiagMonitor 131 5 8 7 Screen savers 134 5 8 8 Defragmentation programs 134 5 8 9 WinCC DataMonitor 135 6 Appendices 137 6 ...

Страница 6: ...Index 151 Table of contents PCS 7 PC Configuration V8 2 6 Installation Manual 03 2016 A5E36200050 AB ...

Страница 7: ...r the secure operation of Siemens products and solutions it is necessary to take suitable preventive action e g cell protection concept and integrate each component into a holistic state of the art industrial security concept Third party products that may be in use should also be considered For more information about industrial security visit http www siemens com industrialsecurity To stay informe...

Страница 8: ...Security information PCS 7 PC Configuration V8 2 8 Installation Manual 03 2016 A5E36200050 AB ...

Страница 9: ...ic PCS 7 applications The software and hardware you require for specific PC components The licenses you require for individual products The potential PC configurations for an application How you can set up and configure your PC network This documentation is intended for persons involved in configuration commissioning and service PCS 7 PC Configuration V8 2 Installation Manual 03 2016 A5E36200050 A...

Страница 10: ...l system and explains the interaction between the individual hardware and software components Note the information on PCS 7 Documentation Portal Setup in the product overview Process Control System PCS 7 PCS 7 Documentation Section Options for accessing the documentation PCS 7 Product Documentation Product documentation contains information about special hardware and software components The indivi...

Страница 11: ...used in the documentation If you use the operating system Windows 10 you can find the Siemens SIMATIC programs in the Start menu under All apps Siemens Automation Changes compared to the previous version Below you will find an overview of the most important changes in the documentation compared to the previous version As of PCS 7 V8 2 Adaptation of the Windows operating systems As of PCS 7 V8 1 Ad...

Страница 12: ...Preface PCS 7 PC Configuration V8 2 12 Installation Manual 03 2016 A5E36200050 AB ...

Страница 13: ...ons for connecting SIMATIC PCS 7 to the SIMATIC IT environment PCS 7 refers to these stations collectively as PC stations The following figure outlines the most important components in a PCS 7 plant QJLQHHULQJ VWDWLRQ 2SHUDWRU VWDWLRQ 0DLQWHQDQFH 6WDWLRQ 7 VWDWLRQ 5RXWH RQWURO VWDWLRQ XWRPDWLRQ V VWHP 6 LVWULEXWHG 2 QWUDQHW QWHUQHW XV WHUPLQDO EXV DQG SODQW EXV 3 6 26 HE 2SWLRQ 6 0 7 3 6 2 352 86 ...

Страница 14: ...ication with the automation system The BATCH station is connected to the terminal bus for this purpose BATCH stations are PCs on which the SIMATIC BATCH software is installed Route Control Station Page 17 You use a route control station RCS to automate the transport of materials and products in a PCS 7 plant The route control station is connected to the plant bus to provide the required data commu...

Страница 15: ...erver Behavior from the client perspective From a client perspective a redundant server pair behaves like one server Configuration You configure all of the configuration data for one server only You then download the configuration data to both redundant servers Configuration limits A redundant server pair behaves like one server You can find additional information on this in the section Difference...

Страница 16: ... You can find information about the client server architecture in the Differences between multiple station systems and single station systems Page 17 section You can find information on how to activate redundancy in the Configuring redundancy for redundant servers Page 81 section You can find information about activating redundancy for operator stations in the manual Process Control System PCS 7 F...

Страница 17: ...on system or a multiple station system with client server architecture Definition of a multiple station system A multiple station system is a system of related PCs in which the functionality of a PCS 7 application in a client server architecture is distributed over several PCs for example OS clients and OS servers The Process Control System SIMATIC PCS 7 DVD provides the associated client or serve...

Страница 18: ...rver as an operator control and monitoring station 1 workstation with a maximum of 4 monitors de pending on the application Maximum number of monitors that can be connected to a workstation 4 depending on the hardware features of the PC You can operate the resulting system areas with a single keyboard and mouse Availability To guarantee high availability of the PCS 7 plant you can configure the se...

Страница 19: ... PCS 7 plant 0XOWLSOH VWDWLRQ 26 FOLHQWV 5RXWH RQWURO FOLHQWV 7 FOLHQWV 06 VHUYHU 7 VHUYHU QJLQHHULQJ 6WDWLRQ 06 FOLHQW RSWLRQDO 5RXWH RQWURO VHUYHU 26 VHUYHU 6LQJOH VWDWLRQ QJLQHHULQJ VWDWLRQ QJLQHHULQJ 6WDWLRQ 0DLQWHQDQFH 6WDWLRQ 26 VLQJOH VWDWLRQ V VWHP 7 VLQJOH VWDWLRQ V VWHP 5RXWH RQWURO VLQJOH VWDWLRQ V VWHP 6 0 7 3 6 2 XV QGXVWULDO WKHUQHW 3ODQW EXV QGXVWULDO WKHUQHW 7HUPLQDO EXV QGXVWULDO ...

Страница 20: ...nd merge the projects at the chart level S7 program to allow several engineers to work at the same time Configuring over a net work Several engineers can work on specific parts of a project for example AS OS stored on a central engineering server at the same time working from their networked engineering stations Example configuration for multiproject engineering QJLQHHULQJ VWDWLRQb QJLQHHULQJ VWDW...

Страница 21: ...rocess Control System PCS 7 SIMATIC PCS 7 BOX 3 5 3 Combination of engineering station and operator station on a single PC Engineering station and operator station on a single PC You can configure a small system such as a training station centrally for all PCS 7 components for example with OS BATCH Route Control AS with a single engineering station You can combine the engineering station and an op...

Страница 22: ...project data process values archives alarms and messages from an OS server or multiple OS servers via a terminal bus OS LAN The OS servers feature additional client functions that allow them to access data on other OS servers their archives messages tags and variables Process pictures from an OS server can then also contain tags of other OS servers You can achieve high availability for the Operato...

Страница 23: ...ccess rights in the network are in place You can find additional information on this in the section Remote access via the Web Option for OS Page 37 Long term archive with Process Historian The Process Historian is used in PCS 7 as an external server for long term archiving of system data You can information on this in the system manual SIMATIC Process Historian Administration Additional informatio...

Страница 24: ...ble to use a multi VGA card for such instances You can achieve high availability for the PCS 7 system by configuring a redundant BATCH server In terms of the number of servers in a PCS 7 project a BATCH server set up as redundant is considered a BATCH server Example configuration 26 FOLHQWV 7 VHUYHU 7 FOLHQWV 26 VHUYHU 26 VHUYHU PD VHUYHUV UHGXQGDQW IRU 6 EDVHG PRGH 6 VWHP EXV QGXVWULDO WKHUQHW 7H...

Страница 25: ...guring a redundant route control server In terms of the number of servers in a PCS 7 project a redundantly configured route control server is counted as a single route control server Example configuration 7HUPLQDO EXV QGXVWULDO WKHUQHW 6 VWHP EXV QGXVWULDO WKHUQHW 26 FOLHQWV 5RXWH RQWURO FOLHQWV PD VHUYHUV UHGXQGDQW 26 6HUYHU 5RXWH RQWURO 6HUYHU Additional information You can find information on c...

Страница 26: ...ent The online status of the hardware can be determined if the MS client is installed on the Engineering Station Up to 4 monitors can be connected to a MS client via a multi VGA card You can operate the resulting system areas with a single keyboard and mouse Example configuration QJLQHHULQJ 6WDWLRQ ZLWK 06 FOLHQW 26 FOLHQWV 06 VHUYHU 26 VHUYHU PD VHUYHUV UHGXQGDQW 26 FOLHQW ZLWK 06 FOLHQW 3ODQW EX...

Страница 27: ...vers and reporting system 3 6 5 1 Process Historian and Information Server The Process Historian is used in PCS 7 as an external server for long term archiving of system data The Information Server is used in PCS 7 as a reporting system for plant data that are archived on the Process Historian Overview of Process Historian and Information Server Process Historian Information Server Function Centra...

Страница 28: ...n a separate PC to ensure the best performance We recommend a RAID system for data security The Process Historian is a node on the terminal bus and is not connected to the system bus Note Installation of the Information Server The Information Server can be installed on the following PC stations On a separate PC On a Process Historian Access protection You can configure access protection with user ...

Страница 29: ...OS single station system OS as single station system on a single PC The OS single station system is an operator station on a single PC with complete operator control and monitoring functionality for a PCS 7 project process cell unit The OS single station system on the system bus can be used in parallel with additional single station or multiple station systems Select one of the following configura...

Страница 30: ...WKHUQHW Plant configuration with multiple OS single station systems Configurations with OS single station systems are possible in SIMATIC PCS 7 The following example shows the maximum configuration for single station systems 1 redundant OS single station system single station system single station system standby Options SIMATIC BATCH Web server client maximum 3 Web clients per OS single station sy...

Страница 31: ...rol messages are displayed on an OS single station system A system spanning overview of the operator and process control messages can be displayed in the Process Historian Information Server 26 VLQJOH VWDWLRQ V VWHPV PD 3 VWDWLRQV HE FOLHQW HE FOLHQW QJLQHHULQJ VWDWLRQ HE FOLHQW 3URFHVV LVWRULDQ 6RIWZDUH 3 6b HE FOLHQW QWUDQHW QWHUQHW 3ODQW EXV QGXVWULDO WKHUQHW 7HUPLQDO EXV QGXVWULDO WKHUQHW Web ...

Страница 32: ...pling to an operator station OS server and for the data communication between the automation systems Two connections are required in AS based operation a A connection to the terminal bus for coupling to an operator station OS server b A connection to the plant bus for coupling the automation systems You use a BATCH single station system to operate and monitor an entire plant When several process c...

Страница 33: ...ingle PC You use the route control single station system to automate the movement of materials and products in a PCS 7 plant You can operate route control single station systems redundantly A connection to an OS server must exist in order to use process mode Note If you use route control single station systems with other route control systems at the same time the areas controlled by a system must ...

Страница 34: ...to connect a dedicated Maintenance Station using standard network adapters on the redundant fault tolerant plant bus read the information about configuration provided in the documentation Process Control System PCS 7 Fault tolerant Process Control Systems Additional information Section Maintenance Station multiple station system Page 25 Section OS single station system Page 29 Section Combination ...

Страница 35: ... name Variant AS selection Description SIMATIC PCS 7 BOX RTX PC station with integrated AS Integrated Software CPU WinAC RTX SIMATIC PCS 7 BOX RTX enables ES OS or OS operation WinAC RTX 2010 supports up to 2000 AS proc ess objects PO SIMATIC PCS 7 BOX PC station with external AS PCS 7 AS RTX SIMATIC PCS 7 BOX enables ES OS or OS op eration WinAC RTX 2010 supports up to 2000 AS proc ess objects PO...

Страница 36: ...ructure for an AS based on PCS 7 AS RTX 2SHUDWLQJ V VWHP 6 0 7 1 7 WKHUQHW RQ ERDUG 3 RQ ERDUG 86 86 QJLQHHULQJ 6WDWLRQ 6 0 7 0 52 2 3 3 3 LQN 9 WKHUQHW RQ ERDUG 352 86 3 352 86 3 LQ 57 Licenses You can find information on licenses for the components of the process control system and possible plant sizes in the installation manual Process Control System PCS 7 Licenses and Configuration Limits PC c...

Страница 37: ...n as a web client or a web diagnostics client Client for process control The following options have been approved for process control with PCS 7 Web client and PCS 7 Web diagnostics client WinCCViewRT Installed with the installation of PCS 7 Web client PCS 7 Web diagnostics client Microsoft Internet Explorer Configurations in PCS 7 plants The following configurations are possible when you use Web ...

Страница 38: ...inal client opens a process terminal session for operation on the terminal server Note Combined Web and terminal server You have to increase the number for the combined Web and terminal server based on the maximum number of terminals clients you want to connect Additional information Information on terminal services is provided in the system manual Process Control System PCS 7 Web Option for OS Yo...

Страница 39: ... 7 uses the following interface formats for data communication OPC UA Unified Architecture OPC DA Data Access OPC A E Alarm and Event and Historical Alarm and Event OPC HDA Historical Data Access OLE DB integration of data in applications that support OLE for example MS Office Additional information Process Control System PCS 7 OpenPCS 7 manual 3 9 Connecting PC stations 3 9 1 Tasks of terminal bu...

Страница 40: ...RO VLQJOH VWDWLRQ V VWHP 7 VHUYHU QJLQHHULQJ VWDWLRQ XWRPDWLRQ V VWHP 6 XWRPDWLRQ V VWHP 6 3ODQW EXV QGXVWULDO WKHUQHW 7HUPLQDO EXV QGXVWULDO WKHUQHW 6 0 7 3 6 2 Topology The terminal bus and system bus can be configured as follows As Industrial Ethernet 10 100 1000 Mbps Bus tree ring star or redundant ring structures Data communication Terminal bus The following table shows data communication in ...

Страница 41: ...on and automation system Operating and monitoring of the processes Automation systems and OS server Route Con trol server communication path CPU CP BUS network adapter CP OS RCS Note Communication with SIMATIC BATCH is from the OS server to the BATCH server via the terminal bus Communication between automation systems SI MATIC communication Automation systems Communication path CPU CP BUS CP CPU S...

Страница 42: ... and network components Distances between the components of a PCS 7 plant Topology operating ranges and parameters Section Basic configuration of the PCS 7 plant Page 13 Section Components for connection to the terminal bus plant bus Page 48 You can find general information about the configuration limits in PCS 7 in the installation manual Process Control System PCS 7 Licenses and Configuration Li...

Страница 43: ...u can find information on the following topics in the configuration manual Process Control System PCS 7 Engineering Station Cables and network components Distances between the components of a PCS 7 plant Redundant bus systems You can use redundant communication paths in PCS 7 You can find information on this in the function manual PCS 7 Fault Tolerant Process Control Systems PC components of a PCS...

Страница 44: ...ring station You can find additional information on this in the section Remote diagnostics functions Page 128 Components for WLAN in PCS 7 The product overview in Process Control System PCS 7 Released Modules lists the network and PC components that are approved for WLAN in PCS 7 You can find the documentation after installation of the PCS 7 Documentation Portal Setup see Preface Page 9 In the Sta...

Страница 45: ...d Modules System manual SIMATIC NET Basics Industrial Wireless LAN 3 9 4 Time synchronization System wide Time Synchronization To obtain process data that can be evaluated all the components of the process control system need to work with an identical synchronized time of day This allows you to assign messages in the correct sequence over time The result is then consistent regardless of the time z...

Страница 46: ...Route Control station SIMATIC PCS 7 BOX PCS 7 internal synchronization is possible The method used depends on the product variant Page 35 operator station or AS AS Synchronization via the plant bus Domain Synchronization via the domain controller as the time master on the terminal bus Time master The time master is integrated in a PC or connected to the Ethernet network as a bus component The time...

Страница 47: ...PCS 7 you can find the relevant hardware requirements in the Basic hardware configuration Page 48 section Color monitors Choose a suitable monitor for PCS 7 Using standard monitors minimum resolution 1280 x 1024 Using widescreen monitors minimum resolution 1680 x 1050 The higher resolution allows you to better utilize the display features of the PCS 7 software for example for the online operation ...

Страница 48: ...occupy a slot in the PC or programming device PG Different network adapters are used depending on requirements Note Bundle PC Observe the requirements for the PC components You can find additional information on this in the Process Control System PCS 7 PCS 7 Readme file see Preface Page 9 Connection to the terminal bus For connection to the terminal bus Released communication modules for the PC st...

Страница 49: ...If you require connections between a PC station with 2 network adapters to fault tolerant automation systems Licensing of the network adapter Licensing for fault tolerant automation systems You can find more information on this in the function manual Process Control System PCS 7 Fault Tolerant Process Control Systems Licensing for the configured terminal bus If you use a CP 16xx on the system bus ...

Страница 50: ... about time synchronization in the function manual Process Control System PCS 7 Time synchronization See also Tasks of terminal bus and plant bus Page 39 4 4 Optional hardware components Note Ordering optional hardware components You will find hardware components which are suitable and approved for PCS 7 in the ST PCS 7 catalog Be aware of any dependencies on the operating system used and standard...

Страница 51: ...Cs and plant bus Intrinsically safe operating unit If required use an intrinsically safe PC operating unit add on product in hazard ous areas zone 1 or 2 distances of up to 750 m are possible Graphics card If multiple monitors are to be operated on a PC you can install an appropriate graphics card Typical applications are PC stations for the following applications An engineering station or A clien...

Страница 52: ...ication The catalog offers turn key solutions Custom solutions For custom solutions for PC systems for example RAID systems contact your Siemens representative in the sales and service locations that are responsible for your company You can find your Siemens contact on the Internet http support industry siemens com aspa_app Hardware for PC stations 4 5 Configuring and ordering PCS 7 PC Configurati...

Страница 53: ...operating system 1 Installing the operating system Page 64 2 Installing operating system service packs Page 69 3 Setting the location where the swap file is to be stored Page 70 4 Making system settings Page 70 5 Installing the Message Queuing service Page 65 6 Installing additional components Page 71 7 Installing the Internet Information Service IIS Page 66 8 Installing additional services for SI...

Страница 54: ...table for short distances in the plant and a limited number of PC stations Authorizations for devices and files are man aged in the AD Authorizations for devices and files are man aged by individual PC stations Administrator The administrator must have comprehensive knowledge substantially higher qualifications The administrator must be familiar with the set up and management of PC stations in the...

Страница 55: ... The recommended solution for name resolution is the use of a DNS WINS server Scenarios Scenarios examples Domain AD Active Directory Workgroup WG New user is added The new user is created centrally in the AD and is then available immediately on all PC stations The new user must be added on each PC sta tion User password is changed The password is changed centrally in the AD The password must be c...

Страница 56: ...onents The MTU size has to be set to 1494 bytes for all components without a PCS 7 installation This can be done on computers without a PCS 7 installation e g domain controller and file server or network components based on Windows e g Automation Firewall using the tool set_mtu_size_to_1494 exe You can find the set_mtu_size_to_1494 exe tool on the PCS 7 DVD 2 in the folder Additional_Products MTU ...

Страница 57: ...d devices have been installed in your PC Check if you have a 32 bit or 64 bit version of the operating system and whether the PC station is suitable for the operating system Check whether the operating system is suitable for the software that you want to install on the PC Check that you have the product key Example PRODUCT KEY XXXXX XXXXX XXXXX XXXXX XXXXX The product key is available in the follo...

Страница 58: ...o overloading of the PC s resources NOTICE Software products of PCS 7 Only install PCS 7 software products listed in this documentation on a PC station This applies in particular to PC stations used for process mode OS SIMATIC BATCH SIMATIC Route Control Installing and simultaneously activating applications that are not approved by Siemens can adversely impact the PCS 7 system performance The user...

Страница 59: ... the data required for the software update Format the hard disks and create new partitions Operating system languages We recommend the following Windows MUI operating systems Multilingual User Interface with the following languages and corresponding regional settings German English French Italian Spanish Chinese When you use PCS 7 you will have to set the required language and region at every poin...

Страница 60: ... following when selecting the operating system language If the PC users only use one language select the operating system language used for configuration process control If the users use multiple languages on the PC select a multilingual operating system English USA by default and then install the additional Multilingual User Interface Packs 5 3 2 Partitioning hard disks Partitioning the hard disk...

Страница 61: ...PCS 7 Readme file see Preface Page 9 5 3 3 Name of the PC station The selection of the computer name is crucial to the project configuration You specify the computer name during installation of the operating system on the computer Specifying the name of the PC station Note Please note when configuring an OS or BATCH server and an engineering station that the following names must be identical Compu...

Страница 62: ...nstalled yourself perform a new installation of Windows Changing the computer name before installation of PCS 7 You can change the computer name in the Control Panel 5 3 4 PC configuration security settings Introduction Current production methods increasingly require process control systems and the IT environment to come together The need to connect company networks to public ones brings with it i...

Страница 63: ... plant is operated in a domain the security settings must match throughout the entire domain Consult with your administrator to agree upon uniform security settings Network You must isolate the network for a PCS 7 plant via switches routers or gateways to ensure that no faults reach the PCS 7 plant via office networks for example You can find information about protecting data exchange between the ...

Страница 64: ... secure networks when connecting to WLANs Make the system specific settings to protect the computer Specify and format hard drives partitions You can find information about this in the section Partitioning hard disks Page 60 If you want to change partitions you may need to delete partitions and create new ones The existing partitions are displayed in Setup Computer name You can find information ab...

Страница 65: ...lso http www siemens com automation service support http www siemens com automation service support 5 3 6 How to install the Message Queuing Service Introduction PCS 7 uses the Microsoft Message Queuing Service This component is part of the operating system MS Message Queuing is not included in the standard installation of Windows however and must be installed separately if needed You need the ins...

Страница 66: ...the start menu to open the Event View 2 In the tree view select Event Viewer Application and Services Logs The Message Queuing Service has been installed correctly if the Source column contains the entry MSMQ Incorrect function If an error message appears under Description in the Event Properties dialog box the installation has not been executed correctly Remove and then reinstall Message Queuing ...

Страница 67: ...ons table below Note Services and options are arranged in a different order in the operating systems Table 5 2 Web services Activate the following Services Options Common HTTP Features Default Document Directory Find HTTP Error Static Content Application Development Application Development Features NET Extensibility 3 5 and 4 6 if available ASP ASP NET 3 5 and 4 6 if available ISAPI Extensions ISA...

Страница 68: ...Compatibility with IIS metabase and IIS 6 configuration Compatibility with WMI for IIS 6 5 3 8 How to Install a Multilingual User Interface Pack Basic procedure Install the required Multilingual User Interface Packs via the operating system You can find information in the section Notes on installing the operating system Page 57 Operating system languages NOTICE Property of operating systems Instal...

Страница 69: ... packs for the operating system Introduction If you installed the operating system without a service pack you will need to install the service pack before continuing Versions Note The version you need is listed in the Process Control System PCS 7 PCS 7 Readme file see Preface Page 9 Requirement Only install service packs if you can reboot the PC station A service pack may reboot the PC station aut...

Страница 70: ...widescreen monitors Minimum resolution 1680 x 1050 The higher resolution allows you to better utilize the display features of the PCS 7 software for example for the online operation of faceplates from the libraries Please ensure that you have installed appropriate drivers and are using suitable monitors For PC stations that are involved in process mode the power saving plan should be set as follow...

Страница 71: ...m Virus scanners approved for the current PCS 7 version Microsoft Office products approved for the current PCS 7 version if needed You must also install additional Microsoft components for some PC configurations Language versions Install the additional Microsoft component in the language version of the operating system The language version of the component can be distinguished by using a language ...

Страница 72: ...CH 5 3 15 Creating a backup Recommendation After restarting and testing the installation create a backup of the partitions on which the operating system PCS 7 software is installed We recommend creating an image of the installation for backing up partitions and hard drive data An image allows you to restore partition and hard drive data at any time or to prepare the PC for a software reinstallatio...

Страница 73: ...kages which you can install from the latest Process Control System SIMATIC PCS 7 DVD in the Process Control System PCS 7 PCS 7 Readme file see Preface Page 9 Latest information about the installation Note Please note the following When installing PCS 7 in a network make sure that at least one DVD drive and one diskette drive are available Read the latest information about installation and the soft...

Страница 74: ... PCS 7 applications such as OS server and BATCH client You can find additional information on this in the appendix Approved configurations Page 142 Installing the Microsoft SQL Server for PCS 7 The Microsoft SQL Server is required in PCS 7 for the specific PC stations for example operator station engineering station As of PCS 7 V7 1 the installation is performed within the PCS 7 system setup and i...

Страница 75: ...IC PCS 7 BOX and SIMATIC IPC note the following When in factory state the settings are made in the registry in DCOM and in the exception list for the Windows firewall The local Windows firewall for the PCS 7 product bundle PC is disabled in the factory state The log of firewall events is disabled Note When the PCS 7 plant is operated in a domain the security settings must match throughout the enti...

Страница 76: ... folder DVD_1 or DVD_2 cannot contain more than 85 characters Make sure the PC is set up to automatically restore the link to the directory containing the PCS 7 software after a PC restart Set up a share for the directory folder or drive on which the PCS 7 software is available Set up the following access rights for the share Operating user Read System Read Procedure 1 Copy the files of the DVD to...

Страница 77: ...after the message is confirmed Install the missing program packages Then restart the PCS 7 system setup Plant with Process Historian as long term archive server Select the following program package for the OS servers that are to export archives to a Process Historian OS Server for Process Historian The Process Historian Ready Component can be installed at a later point in time on an OS server if i...

Страница 78: ...Setup language e g English and Next 2 Welcome Next 3 Product information Read this if needed and click Next 4 License agreement Select the check box I accept the conditions of the above license agreement as well as the conditions of the Open Source license agreement I confirm that I have read and understood the security information Next 5 Setup type Activate the Install or Update check box and cli...

Страница 79: ...of the license agreement check box Next 12 System settings Specific system settings and security settings are required for PCS 7 These settings apply for example to the registry DCOM OPC applications and the Windows Firewall exception list An installation of PCS 7 is not possible without the required settings Select the I accept the change to the system settings check box 13 Ready to install the s...

Страница 80: ... search box in the start menu You can find the installed software packages in the Products tab Virus scanners updates and Microsoft Office products You can find information about this in the section How to install additional components Page 71 PC station as a file server for storing projects for multiproject engineering Note An engineering station must be installed on a server operating system for...

Страница 81: ... in each case you can switch between the two configurations Sybase server as service and Sybase server as user application Then set up the access rights to the shared folder in which you will make your project data available on the central server computer for multi user operation Insert the SYSTEM user in the share permissions and allow full access Restart the computer in order for the settings to...

Страница 82: ...olerant Process Control Systems 5 4 7 Installing a PC for Web Option for OS Installation of PCS 7 Web server and PCS 7 Web client You can find all the information and step by step instructions for installing the following PC stations in the Process Control System PCS 7 Web Option for OS manual PCS 7 Web server PCS 7 Web client PCS 7 Web diagnostics server PCS 7 Web diagnostics client Additional in...

Страница 83: ...rs Operator Operator groups BATCH Engineer ing SIMATIC BATCH BATCH project engineer Route Control Engi neering RC_ENGINEER RS_MAINTENANCE RC_OPERATOR_L1 RC_OPERATOR_L2 RC_OPERATOR_L2 Route Control project engineer Route Control administrator with all rights Operators You can find additional information about operator authorization in the Process Control System PCS 7 SIMATIC Route Control Manual Ru...

Страница 84: ...that work with PCS 7 PCS 7 OS or Route Control projects must be a member of this group Post installation of STEP 7 STEP 7 Siemens TIA Engineer Post installation of STEP 7 products e g service packs User management options Distinguish between the following User management in Windows without SIMATIC Logon User management on a single PC User management performed from a central location in Windows PCs...

Страница 85: ...erating in a domain an additional global user group can be set up for the domain and made a member of the SIMATIC HMI user group A domain administrator is responsible for creating users and groups in a domain This administrator must have the necessary experience and authorization to administer the network Domains administrators have special permissions in PCS 7 systems for managing the network for...

Страница 86: ... PCS 7 versions If you install or remove an older version of the PCS 7 Library PCS 7 Basis Library or PCS 7 Advanced Process Library following the installation of PCS 7 you must re install the current versions of PCS 7 Basis Library or PCS 7 Advanced Process Library by means of the PCS 7 general setup afterwards Do not use the product setup of these libraries to do this You can find PCS 7 librarie...

Страница 87: ...here the PCS 7 projects are or will be stored under Storage location Confirm with OK Restrictions to standard Windows user permissions The following permissions are restricted for users who only have standard Windows user permissions after the installation of PCS 7 Access to the system information of the System info WinCC channel Windows users with standard user permissions must be included in the...

Страница 88: ...nt bus Page 48 Section How to access PC stations outside a subnet Page 112 5 4 12 Subsequent installation or updating If a PCS 7 software package is already installed on the PC a dialog box for the type of installation appears during the PCS 7 system setup You can specify which type of installation you require in this dialog box Installation Update Installation Subsequent installation allows you t...

Страница 89: ...on costs due to more efficient workflow Significant reduction of administrative overhead due to centralized management of the software versions of all PC stations in a PCS 7 plant Easy and reliable use through Clear and self explanatory representation of the action states of different PC stations in a PCS 7 plant No unintentional negative impact on productive operation thanks to upstream security ...

Страница 90: ...Installation of drivers for PCS 7 5 5 1 Drivers for communications processors 5 5 1 1 Drivers for communications processors Introduction The PCS 7 setup automatically installs the required drivers for the communications modules on computers approved for PCS 7 This is only possible when the communications modules have been be inserted in the PC prior to installation of PCS 7 If the type of communic...

Страница 91: ...dure Make sure there are no inconsistencies in Ethernet CPs switches and network adapters in terms of their settings properties for data transmission rate and bus access procedure We recommend using the default setting Autonegotiation procedure for automatic negotiation for the best transmission mode for two directly interconnected network interfaces You can find additional information on this in ...

Страница 92: ... is not a communication module of type CP 16xx Procedure 1 Select the protocol for communication via the respective network adapter in the properties dialog of the network connections Recommended protocol Terminal bus TCP IP Internet protocol version 4 TCP IPv4 System bus SIMATIC Industrial Ethernet ISO 2 For PCs with several network adapters Select the advanced settings Move the network connectio...

Страница 93: ...diagnostics of network components on the system bus with a maintenance station MS A communication module is used on the PC of the maintenance station for access to the system bus An automation system in a SIMATIC PCS 7 BOX is to be loaded using an external engineering station A communication module is used on the engineering station for access to the system bus You can learn which communication mo...

Страница 94: ...rnet Protocol TCP IP Properties dialog box opens 5 Activate the Use the following IP address check box Configure the following fields for the specific plant IP address Subnet mask 6 Click OK 7 Close the dialog box Network Connection Properties by clicking OK Result The network settings for the NDIS adapter are now applied 5 5 2 Additional Devices and Drivers for PCS 7 5 5 2 1 Overview of additiona...

Страница 95: ...cess Control Sys tems Time signal via DCF77 Driver Additional information Time reception service Section How to activate the DCF77 reception service Page 97 Documentation Process Control System PCS 7 Time synchronization Acoustic or visual signal generator Driver Additional information Horn module The required drivers are automatically installed with PCS 7 Documentation Process Control System PCS ...

Страница 96: ...d operating systems Note Installation of the drivers Make sure that you do not use the hardware wizard to install the drivers Start the setup by means of the Windows Explorer Recommended multi monitor graphic cards You can find recommendations for this in the product overview Process Control System PCS 7 Released Modules Additional information The recommended multi monitor graphics cards are inten...

Страница 97: ...ditional information about configuring sounds and assigning them to events in the configuration manual Process Control System PCS 7 Operator Station 5 5 2 4 How to activate the DCF77 reception service DCF77 reception service The DCF77 reception service performs the following tasks Evaluation of time signals from the DCF77 transmitter of the Physikalisch Technische Bundesanstalt in Mainflingen in D...

Страница 98: ...e A license provides the right to use products This right is in the form of CoL Certificate of License License key CoL Certificate of License The CoL certifies the license The product may only be used by the license owner or authorized persons License key The license key is the technical representative of the license also called an elec tronic license stamp License properties Each license consists...

Страница 99: ... of process objects Calculation The number of process objects loaded into the AS is calculated by the exe cuting application and is subtracted from the available process objects in the value X The value X is always updated by the executing application The value for reducing configured process objects can therefore increase again The value Y always indicates the maximum licensed number of process o...

Страница 100: ...e for up to 14 days as a trial version Note You can activate the trial demo mode the first time the software is used Missing license key When a software program requests a license key but it cannot be located on the network in a valid format it is described as a missing license key Automation License Manager You can manage license keys centrally with the software Automation License Manager When yo...

Страница 101: ...able disks for example USB stick but not CDs or DVDs Note Authorizations licenses for older versions of software packages cannot be backed up on a license key USB stick or another USB stick Options for transferring license keys The Automation License Manager gives you the following options for transferring license keys between the various possible storage locations Drag and drop Cut and paste Offl...

Страница 102: ... where you wish to copy the license keys 5 Select the menu command Edit Paste The license keys are transferred Procedure Offline transfer The Automation License Manager online help describes how to perform an offline license key transfer Defective cluster on hard disk Note As part of the license key safety system when license keys are transferred clusters identified as defective are created on the...

Страница 103: ...tral engineering station ES These settings first have to be made on the central engineering station Step What 1 Creating the Logon_Administrator user group for SIMATIC Logon Page 105 2 Setting the language for a user MUI Page 106 3 Setting the communication module for connecting to the terminal bus Page 107 4 Setting up the connection between the PC station and plant bus Page 109 5 Setting the sta...

Страница 104: ...h a chip card and remove this chip card during configuration in the SIMATIC Logon role management all the changes that you have not saved up to this point are discarded Reinserting the card will not solve this problem Notes on the Windows workgroup If you require high availability you need to work in a domain structure since no redundancy is offered by SIMATIC Logon in a Windows workgroup Notes on...

Страница 105: ...l PC In the Logon_Administrator Windows group in the Active Directory Note The local Windows group Logon_Administrator is created automatically when you install SIMATIC Logon Basic procedure 1 Open the user management 2 Select the Logon_Administrator group in the list 3 Assign all users who want to work with the Configure SIMATIC Logon dialog box to the Logon_Administrator group Note You should on...

Страница 106: ...ditional information Manual SIMATIC SIMATIC Logon 5 7 4 Setting the user language MUI Introduction To work with PCS 7 optimally we recommend that you make all the language settings to meet the needs for the specific system In PCS 7 you can set the interface language to one of the following for the engineering system and for process mode depending on the languages installed Chinese German English F...

Страница 107: ...Plus have been installed you can change the language for the default user Reboot Reboot the PC station if you are prompted by Windows to do so after you have changed the language 5 7 5 How to set the communication module for connecting to the terminal bus Introduction Below you can find information about how to select the communication modules for connecting to the terminal bus you will use to con...

Страница 108: ...op of the list You can find additional information on this in the manual Process Control System PCS 7 Fault tolerant Process Control Systems Note Once new network adapters have been installed the most recently entered connection appears at the top of the list Ensure that the connection via which the PC station on the terminal bus communicates is at the top of the list 4 Click OK Specifying the net...

Страница 109: ...properties for Internet Protocol Version 4 TCP IPv4 5 In the Network and Sharing Center select the menu command Change advanced sharing settings The Change sharing options for different network profiles dialog box opens 6 Expand the displayed information for the Home or Work network profile 7 Select the following check boxes Turn on network discovery Turn on file and printer sharing Disable Public...

Страница 110: ...pter for Communication with the System Bus General 2 Standard Set the operating mode to PG mode for every PC network module you want to configure 3 In the tree view select Modules Name of Network Adapter for Communication with the System Bus Address 4 Set the addresses either TCP IP address or MAC address depending on the protocol PC station on system bus connected via standard network adapter If ...

Страница 111: ...n the shortcut menu The S7ONLINE properties dialog box opens 4 Check the entry in the Assigned interface parameter assignment box PC internal local must be set Change the settings if necessary 5 Click OK Additional information You can find information about suitable standard network adapters and CP 16xx communications processors in the product overview Process Control System PCS 7 Released Modules...

Страница 112: ...d network limits PC stations can be located in different subnets in a network The Subnets can for example be connected by routers and protected by a firewall You need to configure the communication paths so that the PC stations in different subnets can communicate with each other Make the settings for the configuration of the PC stations in the SIMATIC Shell If a firewall protects the networks you...

Страница 113: ... WinCC ProjectManager 3 In the Scope tab in the properties add the IP addresses or IP scopes of the communication partners to Remote IP address Requirement Make the following settings as an administrator Procedure 1 In the tree view of Windows Explorer select the SIMATIC Shell folder on the PC station Windows 10 This PC folder Devices and Drives area 2 Select the Settings command from the shortcut...

Страница 114: ...hanging settings for encrypted communication Page 114 5 7 10 Changing settings for encrypted communication As of PCS 7 V8 1 you can use encrypted communication between the PC stations OS and OS or ES and OS that are involved in process mode Encrypted communication makes it difficult for potential attackers to determine information about the process mode or to interfere with process mode When this ...

Страница 115: ... PC stations for which the unencrypted connection is ena bled or the encrypted communication with the same pre shared key If communication is required through both encrypted and unencrypted connections for a PC station you can enable migration mode Note Only use migration mode as a temporary solution Recommended objective for the plant encrypted commu nication between all PC stations of the plant ...

Страница 116: ...on changing a PSK in a plant You can find information on this in the section How to change the PSK for encrypted communication Page 117 Additional information Section How to access PC stations outside a subnet Page 112 5 7 11 How to configure encrypted communication between the PC stations You can enable encrypted communication for the stations that actively engage in process mode Operator station...

Страница 117: ...ilable port instead of the port allocated by default you can specify the assignment of incoming ports 8 Check setting for the Migration mode check box Read the section How to use migration mode for changing encrypted communication Page 119 9 Click OK Additional information Section How to access PC stations outside a subnet Page 112 Online help Simatic Shell 5 7 12 How to change the PSK for encrypt...

Страница 118: ...ode for all PC stations Leave the PSK unchanged and clear the Migration mode check box Example Communication with inconsistent settings for encrypted communication in a plant Example of an initial situation System Communication PSK Server_A Encrypted migration mode enabled AAA Client_1 Encrypted migration mode enabled AAA Server_B Encrypted migration mode enabled 111 Client_2 Unencrypted Reaction ...

Страница 119: ...ommunication Page 117 Reacting to an inconsistent setting for encrypted communication Enabling encrypted communication in a plant Make sure that the following requirements are met For redundant servers the redundancy synchronization is completed before each step Process mode is ended on the relevant PC station Perform each step for all PC stations in the entire plant before performing a further st...

Страница 120: ...cation option in the properties of the PC station in Simatic Shell Additional information Section How to access PC stations outside a subnet Page 112 Section Changing settings for encrypted communication Page 114 Online help Simatic Shell 5 7 14 How to Change the Transmission Rate and Operating Mode in the PC Network Introduction For communication in a network ensure the following parameters are s...

Страница 121: ...ission link Requirement The Autonegotiation setting needs to be changed if nodes which do not have access to this setting must be communicated with in the network Configuring network nodes Location of use Network node Opening the configuration dialog window Parameter setting PC Communication mod ule e g CP 16xx For automatic negotiation of the configured network parameters autonegotiation Activate...

Страница 122: ...are packages which serve to eliminate security vulnerabilities unwanted software properties and similar Information is provided with the software package explaining the properties that need to be changed and the requirements for its installation Note You will find information on the software version for the current PCS 7 version in the pcs7 readme file Microsoft security patches Siemens tests the ...

Страница 123: ... on the components that are to be monitored with the maintenance station Enabling SNMP enabling Windows function Enable only the protocol or the service listed in the table Operating system SNMP or SNMP service Windows 7 Windows 10 Simple Network Management Protocol Windows Server 2008 R2 Windows Server 2012 R2 SNMP service Configuring SNMP 1 Open Services under Computer Management 2 Select the it...

Страница 124: ...er the name used in the configuration under Accepted community names with read write authorizations if you do not install the following software on this system DiagMonitor Page 131 Additional information Setting up cross network communication links You should follow the recommendations in the following document if you wish to set up cross network communication links White paper Process Control Sys...

Страница 125: ...s and Route Control servers Null modem cable to COM interface or network cable cross over cable to an additional Ethernet network adapter Selecting the redundancy interface If you want to establish a redundancy connection between two PC stations OS servers for example you need to select the connection path to the redundant partners A redundancy connection can be established via the serial port or ...

Страница 126: ... manual Process Control System PCS 7 Fault Tolerant Process Control Systems Additional steps for clients OS BATCH Connect the clients with the redundant servers 1 Follow the instructions in the function manual Process Control System PCS 7 Fault Tolerant Process Control Systems Additional steps for SIMATIC Route Control 1 Follow the corresponding instructions contained in the manual Process Control...

Страница 127: ...y points for fast user switching 4 Apply the settings The Fast user switching function is no longer available in the Windows Start menu after logoff 5 7 19 Downloading the network configuration to the PC stations Introduction To allow you to configure download and test all automation systems and PC stations OS BATCH RCS of a PCS 7 project from a central engineering station ES make the following ne...

Страница 128: ...mote diagnostics functions Security requirements If you want to perform remote diagnostics on a PCS 7 plant you must protect that plant against unauthorized access Several steps have to be taken in order to implement a security concept Only when taken together as a whole will these security measures offer the plant optimum protection Transmission paths Data can be transmitted on the following path...

Страница 129: ...aintenance of PCS 7 clients No server services for example Web Navigator Server Data Monitor Server OPC server should be running on these computers The reason for this lies in the handling of remote desktop sessions with the Microsoft operating system The RealVNC software should be used for remote access to other computers in a distributed PCS 7 plant for example OS servers engineering stations No...

Страница 130: ...rminal service Additional information Section Subsequent installation or updating Page 88 White paper Process Control System PCS 7 Security Concept PCS 7 and WinCC Basic Document You can find information on availability in theProcess Control System PCS 7 PCS 7 Readme see Preface Page 9 Operating system online help 5 8 3 Automatic logon to the operating system A PC station with password protection ...

Страница 131: ...archiving devices for example CD DVD burners on the engineering station Usage If you have purchased an engineering station as part of a product bundle this package will include burner software This burner software can be installed after the main installation During installation follow the instructions of the burner software manufacturer 5 8 6 DiagMonitor Introduction The DiagMonitor software is us...

Страница 132: ...ocol family Installing and configuring DiagMonitor software overview Information on the software version of the latest PCS 7 version is available in the Process Control System PCS 7 PCS 7 Readme file see Preface Page 9 Note Version of DiagMonitor software already installed Check the Control Panel to see if a version of the DiagMonitor software is already installed If an older version of DiagMonito...

Страница 133: ...abled 1 Run the following file Start exe 2 Select the WebServer option 3 Confirm the license conditions 4 Confirm the security settings 5 Wait until the installation process is complete 6 Run the following file CM_Activate exe 7 Reboot the computer Configuring SNMP Configure SNMP Follow the procedure described in section Enable and configure SNMP Page 123 Note Domain controller on SIMATIC IPC with...

Страница 134: ...ore cause the system to be overloaded The screen saver reduces the amount of RAM that can be used continuously There are screen savers with which the amount of RAM used by the screen saver is not freed up If you use a screen saver you should deactivate it when operating PCS 7 5 8 8 Defragmentation programs Information about authorizations Authorizations cannot be saved on a license key USB stick I...

Страница 135: ... serves as a central information portal for user specific views On a Web Center page the user can assemble and save the displayed objects of the DataMonitor the so called Web parts as screen views In addition the user manages access to the DataMonitor and process data in the Web Center The Trends and Alarms function is used to display and analyze historical data from the WinCC Runtime Central Arch...

Страница 136: ...tor in the online help for SIMATIC WinCC DataMonitor Path on the DVD Process Control System SIMATIC PCS 7 23_DataMonitor__V Documents Sprache Installing PC stations 5 8 Notes on add ons and utilities PCS 7 PC Configuration V8 2 136 Installation Manual 03 2016 A5E36200050 AB ...

Страница 137: ...ration of continu ous automation functions in accordance with IEC 61131 3 with test and com missioning functions SFC Sequential Function Chart SFC For the graphical configuration of sequential production sequences step sequencers with test and commissioning functions PH Plant Hierarchy PH For displaying a project in a plant view which enables the user to gain a quick overview of project resources ...

Страница 138: ...ons Brief description of the operator station applications The following applications are installed during the PCS 7 system setup from the Process Control System SIMATIC PCS 7 DVD for operator stations License keys are required for use You can find additional information on this in the section PCS 7 licenses and quantity structures Page 98 Program name Brief description Automation License Manager ...

Страница 139: ...ver BATCH client The Batch Control Center BatchCC is the central component in SIMATIC BATCH for batch scheduling and batch control BatchCC manages all the data of relevance for SIMATIC BATCH enabling you to also log all data in the BatchCC The BATCH recipe editor is responsible for creating simple graphics and managing any number of recipes BATCH REPORT The convenient BATCH printing function BATCH...

Страница 140: ...d as an interface between the Route Control center and or PCS 7 OS and the automation systems Additional information License key levels Installation manual Process Control System PCS 7 Licenses and Configuration Limits Section Licensing Page 98 Route Control Library Contains interface blocks for interconnection with user and other process blocks and faceplates for monitoring and operating routes o...

Страница 141: ...s managed with SIMATIC Logon Enable and log functions SIMATIC PDM Configuration parameter assignment commissioning and diagnostics of intelligent process devices SIMATIC PDM allows a number of proc ess devices to be configured under one common user interface SIMATIC Logic Matrix Editor Realize logic operations for control signal Web Navigator For remote publishing of images and other relevant data...

Страница 142: ...gurations with engineering station clients and single station system Page 146 as an OS server and operator station client installation on server Page 148 as an OS server and BATCH server server on server Page 147 Standard configurations The following program packages are offered in the PCS 7 system setup when a PC station is installed Engineering For an engineering PC PCS 7 Engineering BATCH Engin...

Страница 143: ...te Installation of an ES on an OS PC If you wish to install an engineering system ES on an existing OS it is absolutely essential to remove the installed PCS 7 OS version first and then perform the Engineering Station installation Notes for the reader on this section Note In this section the activation of a standard configuration refers to the activation of an application for example activation of...

Страница 144: ...ed clients Maintenance station The maintenance station can be configured as a single station or multiple station system You can configure the MS server with PCS 7 servers on a PC station in accordance with Table 2 below The engineering station or an OS client can be used as MS client External archive server Process Historian In formation Server The Information Server can be installed on a Process ...

Страница 145: ... 7DEOH RQILJXUDWLRQV ZLWK HQJLQHHULQJ VWDWLRQ FOLHQWV DQG VLQJOH VWDWLRQ 3RVVLEOH VHUYHU VHUYHU FRQILJXUDWLRQV DUH VKRZQ LQ 7DEOH RQILJXUDWLRQV ZLWK VHUYHU RSHUDWLQJ V VWHP VHUYHU WR VHUYHU 3RVVLEOH VHUYHU FOLHQW FRQILJXUDWLRQV DUH VKRZQ LQ 7DEOH RQILJXUDWLRQV ZLWK VHUYHU RSHUDWLQJ V VWHP FOLHQW LQVWDOODWLRQ RQ VHUYHU Example configuration Example configuration for a redundant small system with fi...

Страница 146: ...ion type B Page 149 6 2 2 Configuration tables 6 2 2 1 Configurations with engineering station clients and single station system Table 1 Configurations with Engineering Station Clients and Single Station System Purpose Engineering station OS single station system OS client BATCH single station system BATCH client Route Control single station system Route Control Client Standard config uration Engi...

Страница 147: ...age 148 Page 149 X Page 148 Page 149 X Page 148 Page 149 Redundant OS server Page 149 X Page 148 Page 149 X Page 148 Page 149 X Page 148 Maintenance server X Page 148 Page 149 X Page 148 Page 149 X Page 148 Page 149 Redundant maintenance server Page 149 X Page 148 Page 149 X Page 148 Page 149 X Page 148 BATCH server X Page 148 Page 149 X Page 148 Page 149 X Page 148 Page 149 Redundant BATCH server...

Страница 148: ... 148 X Page 148 Redundant main tenance server Page 149 Page 149 X Page 148 Page 149 X Page 148 Page 149 X Page 148 BATCH Server Page 149 X Page 148 X Page 148 Page 149 X Page 148 X Page 148 X Page 148 Redundant BATCH server Page 149 Page 149 X Page 148 Page 149 X Page 148 Page 149 X Page 148 Route Control server Page 149 X Page 148 X Page 148 X Page 148 X Page 148 Page 149 X Page 148 Redundant Rou...

Страница 149: ...tly used as an engineering station and an OS client During configuration process mode of the OS client must be terminated and vice versa Notes on configuration You need to configure a separate OS client in SIMATIC Manager for this OS workstation You cannot and do not have to load the OS client project Notes on process mode The SIMATIC Manager must be closed when the client project is opened Otherw...

Страница 150: ...Appendices 6 2 Appendix B Approved configurations on a PC station PCS 7 PC Configuration V8 2 150 Installation Manual 03 2016 A5E36200050 AB ...

Страница 151: ...the transmission rate 120 Chip card reader USB port 50 Using SIMATIC Logon 50 Using WinCC User Administrator 50 Commissioning 71 Setting the color scheme 71 Setting the font size 71 Commissioning wizard 109 Communication encrypted 112 Communication module 107 Connecting to terminal bus 107 Disabling energy saving option 93 Driver 90 NDIS adapter 93 Operating mode 120 Redundant 51 107 Selecting 107...

Страница 152: ... B 149 Type X 148 Information Server See Archive server Installation 147 Installation 53 57 60 77 81 Message Queuing Service 65 Partitioning hard disks 60 PC 53 PCS 7 73 76 77 Process Historian 81 Software 60 Subsequent 88 Update 88 Installing 72 Services for SIMATIC BATCH 72 Intrinsically safe operating unit 51 IWLAN 44 L Language settings 106 License 9 98 Type 98 License key 98 101 Transferring ...

Страница 153: ...tallation 60 Pay per use license 99 PC 53 Hardware 53 Installation 53 Software 53 PC configuration 35 62 Security settings 62 SIMATIC PCS 7 BOX 35 PC station 103 109 127 142 Approved configurations 142 Commissioning wizard 109 Connecting the system bus 109 Connecting to terminal bus 107 Name 61 Network configuration 127 Overview of the preparations 103 PCS 7 77 Installation 73 76 77 Software 73 PC...

Страница 154: ...25 Redundancy 107 Single license 99 Single station See Single station system Single station system 17 29 Engineering station 21 Operator station 21 29 PCS 7 BOX 35 Route Control 33 Single station system Maintenance Station 34 SIMATIC BATCH 32 Smart card 95 SOFTNET CP 92 Software 53 74 137 138 140 Basic engineering 137 Installation 60 Non Siemens 74 Operator station 138 Optional 140 PC 53 PCS 7 ins...

Страница 155: ...in groups 82 User groups 82 User management User Utility 128 Defragmentation program 128 Screen savers 128 V Validity 9 Virus scanners 128 VXM 141 W Web client 37 Operator station 37 Web Navigator 141 Web View Publisher 141 Wireless LAN 44 WLAN 44 Index PCS 7 PC Configuration V8 2 Installation Manual 03 2016 A5E36200050 AB 155 ...

Страница 156: ...Index PCS 7 PC Configuration V8 2 156 Installation Manual 03 2016 A5E36200050 AB ...

Отзывы: