21-008 !Clock OFF
ISDN clock lost.
Check that the clock is
available on the S
0
/S
2M
line.
If necessary, use HiPath
3000/5000 Manager E to
correct the clock’s allowed/
denied numbers list (Trunk
– Clock parameters).
If necessary, perform a
hard restart (reset).
21-011 !Fan Alarm ON
Fan error.
Check the fan and air sup-
ply in the 19” housing.
Note the ambient tempera-
ture.
21-012 !Fan Alarm OFF
The fan error has
been corrected.
None
21-013 !no ack from
temp. sensor
No response from
temperature sen-
sor.
21-014 !overload at code
receiver
Not enough DTMF
receivers.
Use a larger system.
21-015 !overload at code
transmit.
Not enough DTMF
transmitters.
Use a larger system.
21-019 !Shorten Msg not
successful
Internal error: An
overlong ISDN
message could not
be shortened by
deleting Facility
IEs.
Set up a trace using infor-
mation from BLS.
Create a stack dump.
Save a snapshot.
21-028 !Power Alarm on
Emergency battery
operation due to
power outage.
Check line voltage.
Note battery capacity.
21-029 !Power Alarm off
Power supply re-
stored.
None