Boards for HiPath 3000
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
3-86
HiPath 3000/5000 V9, Service documentation
boards.fm
Peripheral boards
Connection types
●
Fiber optic cable
The fiber optic cable is only connected via the front panel. The opto-electronic converter
must be used to connect a fiber optic cable to the 15-pin Sub-D jacks on the front
panel.
●
Copper cable
The copper cable is only connected via the 15-pin Sub-D jacks on the front panel.
Notes:
●
The connection type setting (fiber optic cable = DIUN2 mod., copper cable = DIUN2) is
made in HiPath 3000/5000 Manager E: System Status – System-wide – Card Config. –
Card data. The connection type setting always applies to both interfaces (line 1 and line 2).
Connection types “DIUN2 mod.” and “DIUN2” cannot be used at the same time.
–
Switch over to the connection type “DIUN2 mod.” with an AMOM adapter plugged in
and an existing fiber-optic connection: The fiber-optic path goes into operation imme-
diately if configured correctly.
–
Switch over to the connection type “DIUN2 mod.” with an AMOM adapter plugged in
and without an existing fiber-optic connection: The fiber-optic path goes into operation
once the fiber-optic cable is plugged in if configured correctly. This can take up to three
minutes.
–
Switch over to the connection type “DIUN2 mod.” without an AMOM adapter plugged
in: If the connection type is switched before the adapter is plugged in, you must per-
form a Reload Card with HiPath 3000/5000 Manager E after plugging in the adapter to
ensure that the adapter is detected by the DIUN2 board.
The DIUN2 board automatically performs a reload after switching from “DIUN2 mod.” to
“DIUN2” or vice versa to load the loadware for the operating mode.
●
Both interfaces can be operated with different versions of the AMOM adapter (see
).
●
Both interfaces can be operated with different protocols.