service.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
12-77
Nur für den internen Gebrauch
Service
Guided Maintenance
18-021 HLM:Lic failure
period stopped li-
cense ok
HiPath License
Management: The
connection be-
tween the system
and HiPath 5000
RSM is reestab-
lished.
None
18-022 HLM: Lic failure
period stopped
default lic
HiPath License
Management: The
connection be-
tween the system
and HiPath 5000
RSM was not rees-
tablished within 30
days. All licenses
were deleted.
Check and reestablish the
connection to HiPath 5000
RSM.
Load license from the CLS
and relicense the system.
Error Class 19 – Network Services Messages
19-002 !SNTP-Server not
responding
No connection to
the SNTP server.
Check the application and
the connection.
Error Class 20 – Call Processing Messages
20-002 !RS232: DSR not
Ready
The RS232/V.24
interface is out of
order.
Check the interface, the
line, and the application.
20-011 !RS232: DSR
ready
The RS232/V.24
interface is now
operational.
None
20-013 !not connected
ways
The maximum
number of connec-
tion paths permit-
ted has been ex-
ceeded.
Use the project planning
tool to test the system con-
figuration.
Set up a trace using infor-
mation from BLS.
Create a stack dump.
Save a snapshot.
Table 12-7
HiPath 3000 Class B Error Messages