power_calc.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
D-5
Nur für den internen Gebrauch
Identifying System Power Requirements
HiPath 3550 Board Power Requirement
S30810-H2956-X200
2.0
1.0
S30810-Q2957-X
2.5
1.5
2
S30810-Q2193-X100
5.0
–
S30810-Q2901-X
1.5
–
S30817-Q922-A301
0.8
–
S30817-Q924-B313
0.6
–
S30817-Q924-A313
1.0
–
S30817-Q932-A
0.5
–
CAS-2
S30810-Q2945-X
4.5
–
S30817-Q923-Bxxx
0.1
–
S30817-Q923-Axxx
0.2
–
S30817-Q926-Axxx
0.4
–
S30810-Q2587-A400
1.8
3
S30810-Q2938-X
Information not available
S30810-Q2918-X
0.1
S30810-Q2917-X
3.8
–
S30810-Q2919-X
0.8
–
S30810-Q2913-X300
0.9
–
S30807-Q6916-X100
0.3
–
S30810-Q2923-X200
0.7
0.7
S30810-Q2923-X100
1.3
1.3
S30810-Q2923-X
2.5
2.5
Detailed configuration rules are provided in section 3.3.12 SLAD16.
2
For each active (off hook) station, the net resource requirement increases by approximately 1.6W (dependent on the tele-
phone’s line length and DC resistance).
3
Identified at a traffic flow of 0.8 Erlang
Table D-4
HiPath 3550 Board Power Requirement
Board or Component
Part Number
Net Power Requirement in
W
5 V
–48 V