start_h3.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
5-3
Nur für den internen Gebrauch
Starting Up HiPath 3000
Starting Up HiPath 3800
Procedure
Run LED HiPath 3800
The CBSAP has a RUN LED that indicates the system status.
Step
Activity
1.
Plug in the power supply cable for the system cabinet(s).
Note (for Brazil only): The AC power of a system cabinet is internally equipped
with transient overvoltage protection up to approx. 2kV. Since additional lightning
protection is prescribed for Brazil, the AC power of the system cabinet(s) must be
conducted through the outlet strip with overvoltage protection (part number
C39334-Z7052-C33). In this way, transient overvoltage protection is guaranteed
up to approx. 4 kV.
2.
Position all LUNA2 power supply switches to “DC-ON”.
Note: Startup does not begin until the switches on all LUNA2 units are in “DC-ON”
position.
3.
Monitor the RUN LED of the CBSAP. The individual steps of the system boot
(Table 5-2) can be observed this way.
Table 5-2
RUN LED - LED Status Meaning
RUN LED
Meaning
Off
No power
On
Reset switch pressed briefly
Off
Reset switch held down for more than 5 seconds (LED is extinguished
to acknowledge that a reload has begun)
On
System boot
Off
for 0.1 s
Load operation: APS in SDRAM, loadware, and card data
Flashing
0.5 s on/0.5 s off
Normal operating state (zero load)
1
1
The flashing rhythm depends on the load. The higher the system load the slower the flashing rhythm.
Flashing
0.1 s on/0.1 s off
MMC removed or defective
>
The HiPath 3800 is ready when the date “1. JAN 00” and the time “00:00” appear in
the display on the system telephone.