Service
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
12-74
HiPath 3000/5000 V9, Service documentation
service.fm
Guided Maintenance
16-011 RESTARTED:
manual Reload
Manual reload.
None
The CDB is reset
to default status.
16-012 RESTARTED:
Power down
No power
Check line voltage.
Check power supply.
16-013 !KDS backup not
performed
Customer data
was not backed up
to MMC.
Check the MMC module
and replace if necessary.
16-014 RESTARTED: un-
known rest. HW-
ind. mismatched
Hardware reports
an unknown reset
reason.
Check environmental influ-
ences (for example,
grounding).
Central control board
problem: -> Replace
board.
16-015 !general error log-
ging
Error while writing
the log file to the
MMC module.
Check the MMC module
and replace if necessary.
16-017 !CTXT take over
failed
Country-specific
texts cannot be ap-
plied.
Retransfer country-specif-
ic texts and change the
language again.
16-020 !CSTA: length out
of range
CSTA interface:
Required length
exceeds the per-
mitted range. In-
correct internal pa-
rameters.
Use the CSTA browser
(application emulation) to
check the CSTA interface.
Set up a CSTA trace and a
default system trace.
Check whether or not the
application has been re-
leased.
16-021 !CSTA: Alloc() er-
ror
CSTA interface: Al-
location fails.
Use the CSTA browser
(application emulation) to
check the CSTA interface.
Set up a default trace with
CSTA.
16-023 APS x fetched
from MMC
Startup acknowl-
edgement after
speed upgrade.
None
Table 12-7
HiPath 3000 Class B Error Messages
No. HiPath
3000/
5000 Manager E:
Event Log Entry
Meaning
Required Measures
Note