Power-Related Capacity Limits
Table 11-4
HiPath 3550 - Maximum Number of Corded Telephones Depending on the
Number of BS3/1s Connected to SLC16N and BS4s Connected to
SLC16N
Number
of BS3/1s and BS4s
connected via
1xU
P0/E
to
SLC16N
Maximum number of corded telephones
Analog telephones
0
1-10
11-20
21-30
31-40
41-50
optiPoint 500
1
66
61
57
53
48
44
2
63
59
54
50
46
41
3
60
56
52
47
43
39
4
58
53
49
45
40
36
5
55
51
47
42
38
33
6
53
48
44
40
35
31
7
50
46
41
37
33
28
8
47
43
39
34
30
26
9
45
40
36
32
27
23
10
42
38
33
29
25
20
11
40
35
31
27
22
18
12
37
33
28
24
20
15
13
34
30
26
21
17
13
14
32
27
23
19
14
10
15
29
25
20
16
12
7
16
27
22
18
13
9
5
Table 11-5
HiPath 3550 - Maximum Number of Corded Telephones Depending on the
Number of BS3/3s Connected to SLC16N and BS4s Connected to
SLC16N
Number
of BS3/3s and BS4s
connected via
2xU
P0/E
to
SLC16N
Maximum number of corded telephones
Analog telephones
0
1-10
11-20
21-30
31-40
41-50
optiPoint 500
1
64
60
56
51
47
42
2
60
56
52
47
43
39
3
57
52
48
43
39
35
4
53
48
44
40
35
31
5
49
44
40
36
31
27
6
45
40
36
32
27
23
7
41
37
32
28
23
19
Содержание HiPath 3000 Series