boards.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
3-61
Nur für den internen Gebrauch
Boards for HiPath 3000
Central Board
Calculating the number of LUNA2 modules required
The number of LUNA2 modules required in relation to the number and type of peripheral
boards installed can be calculated using the following table.
Examples for a one-cabinet system:
a)
Basic cabinet with CBSAP and peripheral boards (without STMI2, SLMA or SLCN)
●
A single LUNA2 can supply a CBSAP and up to four peripheral boards.
●
A second LUNA2 is required for five or more peripheral boards.
●
A third LUNA2 can be used as a battery charger or as a redundant LUNA2.
b)
Basic cabinet with CBSAP and peripheral boards (with STMI2, SLMA and/or SLCN)
●
Two LUNA2s are always required to supply a CBSAP, peripheral boards and
STMI2, SLMA and/or SLCN.
●
A third LUNA2 can be used as a battery charger or as a redundant LUNA2.
Table 3-23
Determining the Number of LUNA2 Modules Required Per Cabinet
Number of peripheral
boards per cabinet
STMI2, SLMA and/or
SLCN available
Number of
LUNA2s required
per cabinet
Basic cabinet
< 5
no
1
< 5
yes
2
5
no
2
5
yes
2
Expansion cabi-
net
< 5
no
1
< 5
yes
2
5
no
2
5
yes
3
10
no
3
10
yes
3
Содержание HiPath 3000 Series