System Data
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
2-36
HiPath 3000/5000 V9, Service documentation
sysdat.fm
HiPath 3000
Trunk Boards
Table 2-19
Trunk Boards for HiPath 3500
Board
Name
Capacity
Coun-
try
Type/Description
P
o
rt
s per board
B channels per board
Max. n
u
mber of
boards per system
RO
W
USA
TCASR-2
2
60
1
1
TCASR-2 provides two E1 CAS interfaces which, combined, can support up to 60 B channels.
As HiPath 3500 supports a maximum of 30 B channels, a total of up to 30 B channels may be used.
1
x
2
2
For selected countries only
-
Board for supporting country-specific
CAS (Channel Associated Signaling) protocols
STLS4R
4
8
#
3
3
The maximum number is calculated on the basis of the system-specific capacity limits, See Section 2.3, “System-Specific
Capacity Limits for HiPath 3000, HiPath 5000”.
x
x Board for ISDN basic access. Permits configuration of ISDN
trunks, tie trunks, and subscribers (no feeding) on the same
board.
TLA4R
4
x
-
Trunk board for analog lines including ALUM and call me-
tering receiving equipment board
TLANI4R
4
x
x Trunk board for analog lines including ALUM
TMGL4R
4
#
-
x Trunk board for analog lines
TS2R
30 30
1
x
-
In HiPath 3000/5000 V5.0 and later, the B channels in the
TS2R board are subject to license. Consequently, the TS2R
board S30810-K2913-Z300 has been assigned a new hard-
ware identification code. The new code prevents the board
from being used in earlier versions. Functionality and layout
of the board have not been changed.
TST1
1
24
1
-
x PRI board
Содержание HiPath 3000 Series