2.5.1
Conditions for specified enclosure rating
To ensure compliance with the specified IP67 enclosure rating of the device, the follow‐
ing requirements must be met. If these requirements are not met, the device does not
fulfill any specified enclosure rating.
•
The side cover of the memory card slot must be placed on and screwed tight to the
device. Recommended tightening torque for the cover screws: 30 Ncm ± 5 Ncm.
•
The cables plugged into the electrical M12 and M8 connections must be screwed
tight.
•
The M8 connection, which may not be used, is sealed with a tightly screwed
protective element, e.g. a protective cap (as delivered).
The same also applies to the EMC requirement (ESD) according to CE.
NOTICE
The type label on the lower side of the device contains a pressure equalizing membrane
attached in the middle. If the type label is damaged or removed, the leak tightness of
the device can no longer be guaranteed.
Positions of the individual elements
2.5.1.1
Exception: temporarily opening the cover on the device
NOTICE
Risk of damage to the product when the cover is open
In open state, the device does not conform to a specified enclosure rating.
If necessary, only operate the device for a short time with an open cover for the
activities listed in the following: During this time, protect the device against moisture
and dust.
Temporarily open the cover for the following activities:
•
Insert or remove the optional storage medium (SD card) for data logging or firm‐
ware update
For this purpose, open the corresponding side cover on the device.
For further warranty provisions, see the General Terms and Conditions of SICK AG, e.g.
on the delivery note of the device.
2.6
Requirements for skilled persons and operating personnel
WARNING
Risk of injury due to insufficient training.
Improper handling of the device may result in considerable personal injury and material
damage.
■
All work must only ever be carried out by the stipulated persons.
This product documentation refers to the following qualification requirements for the
various activities associated with the device:
2
SAFETY INFORMATION
10
O P E R A T I N G I N S T R U C T I O N S | RFU61x IO-Link
8026854//2021-09-01 | SICK
Subject to change without notice