Display
LED
Color
Status
microSD
Off
–
No memory card inserted or card defective
Lights up Green
The memory card is inserted and ready for operation.
•
In this state, the device can either write data to the
memory card or read data on the card.
•
If the LED lights up, however, this does not indicate
that the device is actually accessing the memory card.
Lights up Red
The memory card is inserted.
However, the device cannot read data on the memory
card.
Possible causes:
•
The memory card does not contain any data
•
The content is not readable
•
The memory card is defective
Lights up Orange
2)
A function is started with SOPAS ET which requires a mem‐
ory card for writing.
However, the memory card is not connected.
Lights up Orange
An operation (firmware update) was started via an ISDU
that requires a memory card.
However, the memory card is not connected.
1)
Flash frequency 1 Hz.
2)
Prerequisite: In SOPAS ET, the “SD card required” function has been activated under the “Service” user
level.
8.2.2
Optical “process feedback” status indicator
The “Process Feedback” status display operates with four LEDs. The LEDs are located
in the corners of the antenna cover,
. The LEDs operate
synchronously when displaying the status.
Table 10: Function of the “process feedback” status indicator in read mode
Color
Behavior
Status
Blue
Lights up for the dura‐
tion of the in-progress
reading interval
Read operation was started by an external or internal
trigger source, device has started an internal reading
interval (event)
Green
Lights up briefly
Device has ended the internal reading interval. Trans‐
ponder detected and optionally selected condition(s)
met -> Good Read (event)
Red
Lights up briefly
Device has ended the internal reading interval. Trans‐
ponder not detected or optionally selected condition(s)
not met -> No Read (event)
Indicator_trigger source during read mode: combination of “Reading Interval/Good
Read/No Read” (default)
8.3
Operation via IO-Link
The device can exchange process data and parameters (also: ISDU, service data) via
IO-Link. To do this, connect the device to a suitable IO-Link master.
The IO-Link interface of the device has the following properties:
Table 11: Properties of the IO-Link interface
IO-Link specification
V 1.1
Minimum cycle time
5.6 ms
Transmission rate
COM3 (230.4 kBd)
OPERATION
8
8026854//2021-09-01 | SICK
O P E R A T I N G I N S T R U C T I O N S | RFU61x IO-Link
39
Subject to change without notice