NOTE
Optional memory card
•
Check whether there is a memory card in the card slot of the device. If yes, remove
the memory card from the faulty device in
de-energized state
.
•
Do not send in the memory card!
NOTE
To enable efficient processing and allow us to determine the cause quickly, please
include the following when making a return:
■
Details of the contact person
■
Description of the application
■
Description of the fault that occurred
10.5
Replacing the device
10.5.1
Device exchange with transmission of the current configuration data
NOTE
In order to replace a device that may have failed quickly and without major configura‐
tion effort, it is recommended to implement a device replacement concept.
IO-Link offers the option of automatically backing up the device parameter values as
a preventive measure using the "Backup/Restore" function in the IO-Link master and
thus keeping them available. The same applies after a change parameterization. After
exchanging a failed device with a device with the same device ID (identical type), the
master automatically parameterizes the exchange device.
10.5.2
Removing the device to be replaced
1.
Mark the position and alignment of the device on the bracket or surroundings.
2.
Disconnect the IO-Link interface of the device from the IO-Link master.
3.
Remove the connecting cable of any external trigger sensor.
4.
Detach device. Remove from the bracket.
TROUBLESHOOTING
10
8026854//2021-09-01 | SICK
O P E R A T I N G I N S T R U C T I O N S | RFU61x IO-Link
45