Transponder
SIG200 (IO-Link Master)
PLC
1
2
3
RFU61x IO-Link
1
PLC
2
SIG200 (IO-Link Master)
3
Transponder, e.g.
part no. 6052186
Prerequisites:
•
IO-Link master, z. B. SICK SIG200, connected to the PLC via fieldbus
•
Common PLC configuration tool, if necessary function block for the device instal‐
led
•
Type-specific IODD of the device (RFU610-107xx) for transmission to the PLC
Procedure
1.
Connect the device (RFU61x IO-Link) to the voltage-free IO-Link master via IO-Link.
2.
Connect IO-Link master to PLC via fieldbus.
3.
Supply IO-Link master with voltage.
4.
Load IODD of the device into IO-Link master.
5.
Optional: Select Data Storage in port configuration of the master.
6.
Configure device as desired.
Support is provided by the type-specific IODD technical information with a tabular
overview of all device parameters and the selectable device parameter values,
.
7.
Commissioning by communication via the function block of the device.
8.
Present a described UHF transponder to the device. Generate continuous reading
with the help of the PLC. Make sure the transponder is optimally aligned to the
device when doing so,
see "Mounting the device", page 27
9.
Check the selected parameter values for suitability in operative use and optimize if
necessary.