Mounting
•
Fasten the device using the 2 fastening clamps supplied or the 2 M5 threaded
mounting holes.
•
Mount the device where they will not be exposed to shocks or vibration. In mount‐
ing situations with strong vibrations, it may be necessary to provide shock mounts.
5.2.2
Mounting instructions for ambient temperature range below 0 °C
The device can also be operated at low ambient temperatures. For details,
.
For the electrical installation procedure
see "Instructions for electrical installation when
the ambient temperature can fall below 0 °C", page 34
NOTE
Do not expose the device to strong air movement, e.g. a ventilation system. The device
may otherwise not be able to provide the required heating power. If necessary, shield
the device from air movement with suitable means.
NOTICE
If the ambient temperature is below 0 °C, please note:
•
Do not
move the connecting cables to the device
5.2.3
Auxiliary equipment required
•
If the two fastening clamps of the enclosed mounting kit do not cover the mount‐
ing situation of the application, the customer must provide a suitable mounting
device (bracket). The bracket requires sufficient load-bearing capacity,
and dimensions adapted to the device,
.
•
2 M5 screws for mounting the device to a bracket if the supplied mounting straps
are not used.
NOTE
The screws are for mounting the device on mounting equipment (bracket) supplied
by the user. The screw length required depends on the mounting base (wall
thickness of the bracket).
When using an optional SICK bracket, the screws for mounting the device on the
bracket are included in the scope of delivery.
NOTICE
Possible damage to the device
Screws that are not suitable for the length of the threaded mounting holes can
damage the device.
•
M5 threaded mounting holes for mounting strap: Do not exceed the maxi‐
mum screw-in depth of 6 mm
•
M5 threaded mounting hole for mounting from the rear: Do not exceed the
maximum screw-in depth of 7 mm
•
Tool and tape measure
MOUNTING
5
8026854//2021-09-01 | SICK
O P E R A T I N G I N S T R U C T I O N S | RFU61x IO-Link
25
Subject to change without notice