Inserting or removing the memory card in the device:
NOTICE
Risk of damage to the memory card
b
To safely install or uninstall the memory card, insert or remove the card only
when the device is
de-energized
. To do this, disconnect the device from the supply
voltage beforehand.
Ensure the IP67 enclosure rating of the device is maintained
fied enclosure rating", page 10
The card slot on the device is located under the cover foil on the side opposite the
electrical connections.
1
2
3
Figure 5: Slot for microSD memory card
1
2 x screw, M2.5 hexagon socket
2
Slot for microSD memory card
3
“USB" connection, can only be used by SICK Service
1.
Switch off the supply voltage to the device.
2.
Loosen both screws on the cover.
3.
Carefully fold up the cover.
4.
Making sure it is in the correct position, insert the memory card into the slot until
it locks into place. When doing so, orient the contacts so that they are facing
towards the device and downwards as per the symbol on the device.
5.
Screw the cover back on. Recommended tightening torque for the cover screws:
30 Ncm ± 5 Ncm.
6.
Switch on the supply voltage for the device.
Removing the memory card from the device:
To safely remove the memory card while the device is running, deactivate the card
using the SOPAS ET configuration software and release it for removal.
•
When using the SiLink2Master from SICK with SOPAS ET, select the
Remove SD card
command under
Analysis/SD card
. Wait for feedback from SOPAS ET.
•
If SOPAS ET is not used, send the corresponding command to the device via IO-
Link. The required command can be found in the IODD RFU610-107xx Technical
Information.
PRODUCT DESCRIPTION
3
8026854//2021-09-01 | SICK
O P E R A T I N G I N S T R U C T I O N S | RFU61x IO-Link