RFU610-107xx
SICK Device ID
Assigned number of the device registered with IO-Link, depending
on the country variant of the device.
See https://io-link.com/en/IODDfinder
•
See Technical Information RFU61x Regulatory Compliance
Information
1)
or
•
Available online at:
Part number (device)
1xxxxxx, depending on country variant of the device
•
See Technical Information RFU61x Regulatory Compliance
Information
1)
or
•
Available online at:
Protocol
IO-Link V1.1 according to IEC 61131-9 standard
2)
Function
3)
Host: Process data, service data (parameterization, diagnostics),
data storage
Process data length
IN (input): 32 bytes
OUT (output): 32 bytes
Data transmission rate
COM3 (230.4 kBd)
Minimum cycle time
5.6 ms
Wake up time
> 300 ms
Operating modes
•
IO-Link mode (COM mode) for data exchange
Digital outputs
•
IO-Link Mode: 1 (Q2)
•
Short-circuit protected, temperature protected, not electrically
isolated from the supply voltage
•
Maximum output current of the device via IO-Link master: I
out
≤ 200 mA
Connecting cable
4)
•
IO-Link mode: Standard 4-conductor industrial cable with two
M12 cable heads. Length max. 20 m
Optical displays
5)
•
4 RGB LEDs (status display) on front top
•
4 x RGB LEDs (process feedback) in the four corners of the
antenna cover. Display function can be set with pre-defined
color assignment.
Configuration
•
With SOPAS ET configuration software via IO-Link master (e.g.
SICK SiLink2 master)
•
With fieldbus controller (PLC) and additional support by SICK
function blocks
6)
1)
Printed version enclosed with the device.
2)
Serial, bidirectional point-to-point connection for signal transmission and power supply.
3)
Process data is transmitted cyclically and service data acyclically.
4)
Not included with delivery of the device.
5)
For displaying device and operational statuses.
6)
Function blocks for PLC types from different manufacturers are available online at:
.
12.3
Mechanics and electronics
Table 17: Technical data for RFU610-107xx: Mechanics and electrics
RFU610-107xx
Connection type
IO-Link
•
Connection 1 (IO-Link): Male connector, M12, 4-pin, A-coded
•
Connection 2 (trigger): Female connector, M8, 4-pin, coded
•
USB interface
1)
•
Interface for microSD memory card
12
TECHNICAL DATA
48
O P E R A T I N G I N S T R U C T I O N S | RFU61x IO-Link
8026854//2021-09-01 | SICK
Subject to change without notice