Product description
36
© SICK AG · Division Auto Ident · Germany · Subject to change without notice
8013796/UL20/2010-09-27
Operating Instructions
Laser Measurement Systems of the LMS500 Product Family
Chapter
3
3.10.1
Ethernet interface
The Ethernet interface has a data transmission rate of 10/100 MBit. The interface is a TCP/
IP interface. Full duplex and half duplex are supported.
The Ethernet interface allows the configuration of the LMS as well as the output of
measured values.
The factory setting for the Ethernet interface is as follows:
•
IP address: 192.168.0.1
•
subnet mask: 255.255.255.0
•
TCP port: 2111
If necessary, adjust the TCP/IP configuration for the Ethernet interface to enable a
connected PC (client) to communicate with the LMS via Ethernet: P
ROJECT
TREE
, LMS…,
N
ETWORK
/I
NTERFACES
/IO
S
, E
THERNET
.
Important
If you change the parameters for the Ethernet interface over the Ethernet interface, you
must first save the data in non-volatile memory in the LMS and then restart the LMS. For
this purpose there is the R
ESTART
button in SOPAS_ET.
You will find a description of the electrical interface in
section 5.2 “Connections of the LMS”
3.10.2
Serial host interface
The serial host interface is an RS-232/RS-422 interface. The host interface permits the
configuration of the LMS and only limited measured value output.
The interface parameters are freely configurable:
P
ROJECT
TREE
, LMS…, N
ETWORK
/I
NTERFACES
/IO
S
, S
ERIAL
, area S
ERIAL
HOST
INTERFACE
.
The factory setting for the host interface is as follows:
•
57,600 Baud
•
8 data bits
•
1 stop bit
•
no parity
Important
If you change the parameters for the host interface over the host interface, the connection
to the device will be lost. You must then scan for the LMS again in SOPAS ET (see
section 6.3.5 “Performing scan” on page 60
You will find a description of the electrical interface in
section 5.2 “Connections of the LMS”
3.10.3
USB auxiliary interface
The mini-USB auxiliary interface permits the configuration of the LMS.
The USB driver provided in the LMS CD must be loaded first.
Parameters can be changed via USB while the scanner is connected to another interface
such as RS or Ethernet to a host. Only the last changes saved in the configuration, either via
USB, RS or Ethernet, will be permanent.