Operating Instructions
LMS500 Product Family
Electrical installation
8013796/UL20/2010-09-27
© SICK AG · Division Auto Ident · Germany · Subject to change without notice
49
Chapter
5
5.2.2
Connections of the LMS511
“Power” connection M12×5, plug
Communication connection M12×12, plug
“I/O” connection M12×12, socket
Pin
Signal
Function
1
V
S
LMS supply voltage
2
V
s
heat.
Supply voltage for the heating
3
GND
Ground
4
–
Not assigned
5
GND heat.
Ground heating
Tab. 11:
Pin assignment of the “Power” connection on the LMS511
2
1
4
3
5
Pin
Signal
Function
1
1)
V
CC
Out 1+2
2
RS422 RxD-
Serial RS
F
422 host interface (receiver)
Out 1
4
RS422 CAN GND
Ground Serial RS-422 and CAN
Out 2
NC
Not connected
7
RS422 TxD-
Serial RS
F
422 host interface (sender)
NC
Not connected
9
RS422 RxD+
Serial RS
F
422 host interface (receiver)
10
RS422 TxD+
Serial RS
F
422 host interface (sender)
11
CAN Low
CAN-BUS Low
12
CAN High
CAN-BUS High
Tab. 12:
Pin assignment of the “RS
F
232” connection on the LMS511
1)
Available from December 2010.
Pin
Signal
Function
1
V
CC
Out 3-6
2
1)
GND In 1+2
In 1
4
GND In 3+4
In 2
6
In 3
7
GND Out 3-6
8
In 4
9
2)
Out 3
10
Out 4
11
Out 5
12
Out 6
Tab. 13:
Pin assignment of the “I/O” connection on the LMS511
1)
Available from December 2010.
2)
SOPAS software must be configured as Out 1. From December 2010 SOPAS will change to Out 3.
Содержание LMS500-20000 PRO Indoor