Operating Instructions
LMS500 Product Family
Technical specifications
8013796/UL20/2010-09-27
© SICK AG · Division Auto Ident · Germany · Subject to change without notice
69
Chapter
9
Dimensions
3)
Height
185 mm
(7.28 in)
Width
155 mm
(6.10 in)
Depth
160 mm
(6.30 in)
Total weight (without connecting cables)
3.7 kg
(8.15 lb)
Electrical data
Supply voltage LMS at the scanner
19.2 V
24 V
28.8 V
Permissible residual ripple
±5%
Supply voltage for the LMS511 heating
19.2 V
24 V
28.8 V
Switch on current
2 A
Operating current at 24 V
0.9 A
Operating current with max. output load
1.9 A
Operating current with maximum heating performance
2.3 A
2.5 A
Power consumption with maximum output load
22 W
25 W
Power consumption with maximum heating
performance
65 W
70 W
Electrical connection LMS511
Round M12 plug connector
Electrical connection LMS500
System plug with screw terminal block
Switching inputs
Number
0 (2)
4)
Encoder inputs
Number
2
Digital switching outputs
Number
3 (6)
Maximum current output 1 + 2
5)
250 mA
Maximum current output 3 + 4
100 mA
Serial auxiliary interface
Communication protocol
USB 2.0
Transmission speed
9,600 Baud
57.6 kBd
115.2 kBd
Serial host interface
Communication protocol
RS
F
232 (proprietary)/RS
F
422
Transmission speed (selectable)
9,600 Baud
57.6 kBd
115.2 kBd
Ethernet
10/100 MBit/s
1)
Corresponds to Diamond Grade 3000X™ (approx. 1,250 cd/lx × m²).
2)
The time after the first reflected pulse from which measurement can be performed with full accuracy is
dependent on the target that reflected the first reflected pulse.
3)
Without fixing screws and projection of cable glands with system plug mounted.
4)
Available from December 2010.
5)
Outputs are short-circuit protected (no overload protection).
Minimum
Typical
Maximum
Tab. 20:
Data sheet LMS500/511 (cont.)