Operating Instructions
LMS500 Product Family
Annex
8013796/UL20/2010-09-27
© SICK AG · Division Auto Ident · Germany · Subject to change without notice
91
Chapter
10
Example 1
Output channel 1 active, each measured data message:
Request:
<STX>sWN{SPC}LMDscandatacfg{SPC}01{SPC}00{SPC}0{SPC}
1{SPC}0{SPC}00{SPC}00{SPC}0{SPC}0{SPC}0{SPC}0{SPC}+1<ETX>
HEX string:
02 73 57 4E 20 4C 4D 44 73 63 61 6E 64 61 74 61 63 66 67 20 30 31 20 30 30
20 30 20 31 20 30 20 30 30 20 30 30 20 30 20 30 20 30 20 30 20 2B 31 03
Answer:
<STX>sWA{SPC}LMDscandatacfg<ETX>
HEX string:
02 73 57 41 20 4C 4D 44 73 63 61 6E 64 61 74 61 63 66 67 03
Example 2
Output channel 2 active, encoder channel 1 active, each 10th measured data message:
Request:
<STX>sWN{SPC}LMDscandatacfg{SPC}02{SPC}00{SPC}0{SPC}1
{SPC}0{SPC}01{SPC}00{SPC}0{SPC}0{SPC}0{SPC}0{SPC}+10<ETX>
HEX string:
02 73 57 4E 20 4C 4D 44 73 63 61 6E 64 61 74 61 63 66 67 20 30 32 20 30 30
20 30 20 31 20 30 20 30 31 20 30 30 20 30 20 30 20 30 20 30 20 2B 31 30 03
Answer:
<STX>sWA{SPC}LMDscandatacfg<ETX>
HEX string:
02 73 57 41 20 4C 4D 44 73 63 61 6E 64 61 74 61 63 66 67 03
Request
Message structure:
sWN FREchoFilter
Message part
Description
Variable type
Length
(byte)
Value range
Type of command
Request (SOPAS write by name)
string
3
sWN
Command
Configure echo filter
string
12
FREchoFilter
Echo filter
Enum8
1
0
First echo
1
All echoes
2
Last echo (default)
Message syntax XX:
Request “Configure echo filter”
Содержание LMS500-20000 PRO Indoor