Product description
38
© SICK AG · Division Auto Ident · Germany · Subject to change without notice
8013796/UL20/2010-09-27
Operating Instructions
Laser Measurement Systems of the LMS500 Product Family
Chapter
3
3.12
Planning
3.12.1
LMS system requirements
For commissioning and operating the LMS, the following are required:
•
LMS500: Supply voltage DC 19.2 … 28.8 V, generated as per IEC 60364
F
4
F
41
(VDE 0100, part 410), output power minimum 24 W
•
LMS511: Supply voltage DC 19.2 … 28.8 V, generated as per IEC 60364
F
4
F
41
(VDE 0100, part 410), output power minimum 24 W.
Supply voltage for the heating DC 24 V, output power minimum 50 W (cyclic)
•
Data interface RS
F
232/RS-422, Ethernet and USB (optional, in case several LMS are
connected together in a network)
•
PC with operating system Windows 2000™, Windows XP™ or Windows Vista™ (see also
section 6.2.1 “System requirements for SOPAS ET” on page 58
)
3.12.2
Mounting requirements
The LMS must be mounted as follows:
•
robust
•
as far as possible without shocks
•
as far as possible without vibration
•
protected from direct sunlight and heat sources
Mounting kits
The following mounting kits are available:
•
mounting kit 1: mounting bracket for mounting at the rear on wall or machine (see
•
mounting kit 2: mounting bracket, only in conjunction with mounting bracket 1, cross-
wise adjustment possible (see
)
•
mounting kit 3: mounting plate, only in conjunction with mounting bracket 1 and 2,
length-wise adjustment possible (see
•
mounting with the Heavy Duty mounting bracket (see
)
Mount the LMS such that it is not exposed to direct sunlight (if necessary fit canopy). In this
way an inadmissible increase in the temperature inside the system is avoided.