Power-up delay
60 s
Of a configured device
15 s
Configurable restart after
2 s
60 s
General data
Laser protection class
Laser class 1 according to
IEC 60825
F
1 (2007
F
3) (complies with
21 CFR 1040.10 and 1040.11 except for
deviations pursuant to Laser Notice No. 50,
June 2007)
Enclosure rating
As per EN 60529 (1991
F
10); A1 (2002
F
02)
LMS500
IP 65
LMS511
IP 67
EMC test
As per EN 61000
F
6
F
2 (2005
F
08),
EN 61000
F
6
F
3 (2007
F
03)
Electrical safety
As per EN 50178 (1997
F
10)
Operating temperature range
LMS500
0 °C (32 °F)
+50 °C
(122 °F)
LMS511
–30 °C
(–22 °F)
+50 °C
(122 °F)
Storage temperature range
–30 °C
(–22 °F)
+70 °C
(158 °F)
max. 24 h
Humidity (taking into account the operating
temperature range)
DIN EN 60068
F
2
F
61, method 1
Vibration resistance
As per EN 60068
F
2
F
6 (1995
F
04)
Frequency range
10 Hz
150 Hz
Amplitude
5 g RMS
Shock resistance
As per EN 60068
F
2
F
27 (1993
F
03),
EN 60068
F
2
F
29 (1993
F
04)
Single shock
15 g (0.53 oz), 11 ms
Continuous shock
10 g (0.35 oz), 16 ms
Sender
Pulsed laser diode
Wave length
895 nm
905 nm
915 nm
Divergence of the collimated beam (solid angle)
High resolution
Standard resolution
3.6 mrad
11 mrad
Housing
Material
GD
F
ALSI12 3.2582.05
Colour LMS500
RAL 5012 (blue)
Colour LMS511
RAL 7032 (grey)
Alloy
Excellent weather resistance as per DIN EN
106:1988, plate 3
Front screen
Material
Polycarbonate
Surface finish
Outside with scratch-resistant coating
Minimum
Typical
Maximum
Tab. 20:
Data sheet LMS500/511 (cont.)