Operating Instructions
LMS500 Product Family
Annex
8013796/UL20/2010-09-27
© SICK AG · Division Auto Ident · Germany · Subject to change without notice
85
Chapter
10
10.2.5
Read scanning frequency, angular resolution and scan area
Reads the scanning frequency, the angular resolution and the starting/stopping angle from
the LMS.
Request
Message structure:
sRN LMPscancfg
Answer
Message structure:
sRA LMPscancfg
ScanningFrequency NumberSegments
AngularResolution StartingAngle StoppingAngle
Example
Request:
<STX>sRN{SPC}LMPscancfg<ETX>
HEX string:
02 73 52 4E 20 4C 4D 50 73 63 61 6E 63 66 67 03
Answer:
<STX>sRA{SPC}LMPscancfg{SPC}0{SPC}9C4{SPC}
1{SPC}9C4{SPC}FFFF3CB0{SPC}1C3A90<ETX>
HEX string:
02 73 52 41 20 4C 4D 50 73 63 61 6E 63 66 67 20 31 33 38 38 20 31 20 31
33 38 38 20 46 46 46 46 33 43 42 30 20 31 43 33 41 39 30
Message part
Description
Variable type
Length
(byte)
Value range
Type of command
Request (SOPAS read by name)
string
3
sRN
Command
Reading of scanning frequency and
angular resolution
string
10
LMPscancfg
Message syntax X:
Request “Read scanning frequency, angular resolution and scan area”
Message part
Description
Variable type
Length
(byte)
Value range
Type of command
Answer (SOPAS read answer)
string
3
sRA
Command
Configuration of scanning
frequency and angular resolution
string
10
LMPscancfg
ScanningFrequency
Information 1/100 Hz
uint_32
4
2,500
25 Hz
3,500
35 Hz
5,000
50 Hz
7,500
75 Hz
10,000
100 Hz
NumberSegments
For the LMS500 always 1
uint_16
2
1
1 segment
AngleResolution
Information 1/10,000 degree
uint_32
4
1,667
0.1667°
2,500
0.25°
3,333
0.3333°
5,000
0.5°
6,667
0.6667°
7,500
0.75°
10,000
1.0°
Starting angle
Information 1/10,000 degree
int_32
4
–50,000
…
+1,850,000
StoppingAngle
Information 1/10,000 degree
int_32
4
–50,000
…
+1,850,000
Message syntax XI: