Operating Instructions
Chapter 4
ICR845-2
Installation
8012377/0000/2008-01-30
©
SICK AG · Division Auto Ident · Germany · All rights reserved
23
4
Installation
4.1
Overview of installation sequence
This chapter describes the installation sequences for the ICR845-2 and the external com-
ponents.
The typical installation sequences are listed below:
Selecting the installation location for the ICR845-2
Aligning the ICR845-2 to the code and installing the device
Installing the connection module CDB620 or CDM420
Connecting the ICR845-2 to connection module CDB620 or CDM420
Adjusting the ICR845-2 (reading distance)
Installing the reading pulse sensor for reading pulse triggering
Important
Do not open the housing of the ICR845-2. If the device is opened, the SICK AG warranty
shall not apply.
4.2
Installation preparations
The following general requirements should be observed for installation:
Typical space requirement: application-specific and type-dependent (reading range,
orientation of reading window)
Unobstructed view of the objects for the ICR845-2
Stable installation holder with sufficient load capacity and dimensions suited to the
ICR845-2 (see
Chapter 9.2 ICR845-2 dimensional drawing, Page 123
)
Shock absorbent and vibration free attachment
The following tools and resources are required for installation:
Two screws M5 for installing the SICK mounting bracket no. 2025491/ no. 2039465 or
the quick release clamp no. 2042484 to the base.
The screw length depends on the wall thickness of the base.
Tool
Goniometer
4.2.1
Components to be installed
The following components have to be placed ready for installation:
ICR845-2 Image Code Reader
4.2.2
Accessories
The following accessories are not included in the delivery of the ICR845-2. They have to be
ordered separately and placed ready for installation:
Mounting device, see next chapter
Connection module CDB620 or CDM420
Reading pulse sensor for external reading pulse triggering, e.g. photoelectric reflex
switch(es)/photoelectric proximity switch