Technical data
9.3
Specification diagram
9.3.1
Reading conditions for the diagram
9.3.2
Reading ranges ICR845-2C0020/-2C1020 (Mid Range)
Test code
Code 128/ Data Matrix ECC200
Print ratio
2:1
Print contrast
Bar codes: > 90 %,
Data Matrix: Grade A accord. to ISO/IEC 16022
Tilt
typical 30 and resolution 0.17 to 0.5 mm (6.7 to 19.7 mil)
Ambient light
< 2,000 lx
Good read rate
> 75 %
Tab. 9-3: Reading conditions for specification diagram
Fig. 9-2:
ICR845-2C0020/ -2C1020 (Mid Range): Reading ranges and dimensions of the field of view
Reading conditions:
see
Table 9-3, Page 124
Focus position 115 mm (4.53 in)
All dimensions in mm (in)