Operating Instructions
Chapter 10
ICR845-2
Appendix
8012377/0000/2008-01-30
©
SICK AG · Division Auto Ident · Germany · All rights reserved
157
10.7.4
Static Teach-in match code 1 and code comparison
For teaching in 1D codes, the ICR845-2 uses temporarily the SMART and standard decod-
ers. To ensure that the match code is read reliably, the ICR845-2 temporarily sets the
number of multiple reads to 30.
Important
If a match code 2 is already configured in the ICR845-2 when using the static teach-in for
match code 1, afterwards the match code 2 remains inactive.
a) Configuring the Static Teach-in
Overview of configuration steps
If necessary, configure the evaluation for mirrored Data Matrix codes in the ICR845-2
Select the mode of Static Teach-in in the ICR845-2
If necessary, activate match code 1 for output filter in the ICR845-2
If necessary, delete an existing match code 1 in the ICR845-2 before teaching-in a new
match code
If necessary, save the taught-in match code also in the external parameter memory
CMC600
Configure "Sensor 2" switching input for triggering the Teach-in in the ICR845-2
Configure the switching outputs in the ICR845-2 for indicating the result status
Download the parameter values to the ICR845-2
Configuring the evaluation for mirrored Data Matrix codes (optional):
1.
Select the C
ODE
C
ONFIGURATION
tab.
2.
Click the E
DIT
button in the 2D S
YMBOLIGIES
section.
The D
ATA
M
ATRIX
tab is then displayed.
3.
Click the M
IRRORED
radio button In der A
PPEARANCE
section.
Selecting the mode of Static Teach-in:
1.
Select the D
EVICE
C
ONFIGURATION
tab.
2.
Click the M
ATCH
C
ODE
P
ARAMETERS
button.
The M
ATCH
C
ODE
P
ARAMETERS
tab is then displayed.
3.
Click the S
TATIC WITHOUT
P
HARMACODE
radio button in the M
ETHOD OF TEACH
-
IN
section
respectively when reading a Pharmacode the S
TATIC WITH
P
HARMACODE
radio button.
(see also
„Teach-in modes for match code 1“
,
Page 150
).
4.
If necessary, click the W
ITH
C
OUNTER
R
ESET
option in the T
EACH
-I
N
section.
Configuring match code 1 for output filter (optional):
1.
Select the M
ATCH
C
ODE
P
ARAMETERS
tab.
2.
Proceed as follows to activate the output filter in the C
ODE
A
CTIVE
section:
– Click the C
ODE
#1 checkbox.
– Click the F
ILTER FOR
H
OST
O
UTPUT
checkbox.
– Click the C
ODE
#1 checkbox again.
The code comparison activated via the user interface is now no longer permanently
activated. The output filter, however, remains active.
Important
If two match codes have been defined and activated, the activation of one of the match co-
des for output filter determines that the ICR845-2 only outputs codes which match with the
code for output filter via the host interface.