Chapter
10
Operating Instructions
CLV 42x bar code scanner
10-6
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 981/O078/16-08-2004
Appendix
10.2.6
CLV 42x characteristics field of scanning frequency
10.3
System messages
The CLV outputs all system messages in plain text via the terminal interface. The messages
are in English and can be displayed in extended mode of the terminal emulator in the
CLV Setup user interface. (
See
Chapter 6.6.1 Displaying messages, Page 6-25
.)
Fig. 10-5:
CLV 42x: scanning frequency characteristic as a function of the reading distance and resolution
Reading conditions:
see
Message
Meaning
"
CLV 42
Soft.Vers. X.XX
Change No. 0000
Host: RS232
"
The software version and revision is displayed when the power
supply is switched on.
"
no code
"
In “Reading/Parameter Evaluation“ mode, the CLV indicates that no
codes matching the parameterized evaluation conditions were
detected during the reading interval.
(error status ST = 2 output on the host interface).
"
laser safety timeout
"
The CLV has deactivated the laser diode 10 minutes (default setting)
after a reading pulse was initiated. The reading pulse is still active,
even though the CLV is no longer reading. The reading pulse is to be
terminated by resetting the pulse signal. The laser diode is activated
again by the next reading pulse.
"cancel AutoSetup"
The CLV has terminated the AutoSetup, no valid bar code was found.
Table 10-2: CLV system messages