The CLV can be installed using the following SICK brackets:
•
Small mounting bracket, no. 2 020 077
•
Large mounting bracket, no. 2 020 078
The brackets are designed to support a variety of installation positions and alignments of
the CLV in two planes.
shows a mounting example.
The slots in the brackets allow a turning freedom of
±
15
°
for the fine adjustment of the CLV.
Fig. 4-2:
Location of the securing threads on the CLV
45.8
(1.80)
72
(2.84)
32.8
(1.29)
59
(2.32)
M4, 6 (.24) deep
M4, 6 (.24) deep
10
(.39)
10
(.39)
35.2
(1.39)
35.2
(1.39)
4
(.15)
4
(.15)
All dimensions in mm (in)