The window is subdivided in the following functional areas (All parameters are described in details
in Tables 2.9 and 2.10):
System Config:
the system configuration (IDU type) is displayed and can be modified by
the operator selecting the values in the combo-box. The new configuration is executed only
when the <Apply> button at the bottom of the area is pressed.
The field
Add new license
is used if a new license has to be installed (license upgrade). In
this case the string provided with the new license has to be entered in this field and the
<Apply> button at the bottom of the area pressed. In the System Status (Settings) the new
license is displayed.
Note: a License downgrade is not allowed.
Clicking on the <Info> button a pop-up window is shown detailing the installed SW license
and the allowed Channel/Modulation configurations i.e. the system capacity supported by
the license (see Fig. 2.9)
Figure 2-9 Info pop-up window about SW licence
Protection:
this area is available only with the PSE/W or PSE/L configuration and only if
the system has been configured as
1+1 HSB Main
or
1+1 HSB Protection
in the system
configuration. It allows to define the specific features associated to the Protection group.
The new settings is executed only when the <Apply> button at the bottom of the area is
pressed.
Note:
All parameters relevant to the Protection Group have to be defined only on the Main
ODU: the Protection ODU is automatically updated in a consistent status by SW. Therefore
the <Apply> button is effective only if the Protection field in the System Conf. is set to 1+1
ODU Main.
Important Warning:
For the correct operation of the Protection Group the Mate Link
connecting the two PSE must allow the exchange of Status information between the two
ODUs. Therefore it is mandatory not to disconnect the Mate Link cable if the Protection
Group is operating in the normal mode to avoid to make Active both systems. If the Mate
Link cable has to removed/replaced, it is mandatory before to put the Protection Group in a
Forced status.
IDU management:
dedicated to the management of the IDU MAC Address required to
associate the IDU to the system. The MAC Address can be either manually entered or auto
discovered by enabling the automatic procedure. In both cases the new MAC Address is
activated only when the <Apply> button at the bottom of the area is pressed.