Note 1): In case the default value 0 is used no C or S Tag is associated to the management traffic. If a specific
VLAN is reserved to the management traffic this value has to be used in all equipment of the whole
L2 network.
Note 2): By the Mode field it is possible to control the remote access capability, defining if
-
only access from a CT (“WebOnly”) is allowed with SNMP interface inhibited
-
both CT and SNMP (for access to an OS) can operate (“osAndWeb”).
see chapter 4 – “Supervision by Remote Craft Terminal (RCT) and Operation System (OS)”
Note 3): Equipment of the radio link located in the Remote station. For 1+1 HSB radio links, as Remote IP
enter the IP address of the equipment having the same protection role in the protection group
Note 4): Only for 1+1 HSB radio links. The other Equipment of the radio link collocated in the local station.
The IP address is automatically set from the Mate equipment when the Mate link is connected.
Note 5): Only for 1+1 HSB radio links. Equipment of the radio link located in the Remote station: as Mate-
Remote IP enter the IP address of the equipment having the opposite protection role in the protection
group
Table 2-10: System Settings parameters