15) Configure Housekeeping and Activate Statistics, Logs and Performance Monitoring as
required
16) If the ODU is part of a Protection Group (1+1 HSB systems) after the ODU is restored to
service the Forced Mode has to be removed acting on the ODU Main and the original
setting of the protection group restored.
Note 1:
No action for antenna pointing readjustment is required.
5.3.2
Replacing the IDU (PSE/W or PSE/L)
In case the replacement of the IDU is required, the following procedure has to be followed.
1)
Take from the stock a spare unit with the same P/N of the unit to replace
2)
In case the IDU (PSE) is part of a Protection Group (1+1 HSB system) the following actions
are required.
First put the system in a Forced status:
i. To replace the IDU of the Main, set in ODU Main
System
Settings→Protection
window (par. 2.10) the field
Forced Mode
to
Lockout
(this operation could not be
possible if the IDU is faulty). Verify that the ODU Protection status in the
System
Status
window is
Active.
ii. To replace the IDU of the Protection, set on the ODU Main (System
Settings→Protection
window (par. 2.10)) the field
Forced Mode
to
Forced
and verify
that the ODU Main status in the
System Status
window is
Active.
If the User traffic is only connected to the USER port of the IDU to be replaced, a manual
reconfiguration has to done, moving the User cable to the USER port of the other PSE in
order to guarantee service continuity and configuring properly the USER interface of this
PSE.
If the User traffic is connected to both USER ports of the two PSE, USER ETH interface
configuration of the PSE remaining in service has to be modified in order to guarantee that
User traffic is only routed through this interface.
3)
Wear the antistatic armlet and connect its termination to a grounded structure.
4)
Turn off (position O) the power switch on the front of the IDU unit to replace.
5)
Disconnect all the cables from the front panel, taking care of putting marking labels (if not
yet present) to facilitate a correct connection afterwards. In case of 1+1 HSB systems also
the Interconnection cable between the two PSE has to be disconnected.
6)
Extract the IDU box from the shelf unscrewing the two screws.
7)
Insert the new IDU unit in the support frame.
8)
Reconnect all the cables on the IDU front in the original position.
9)
Turn ON (position I) the power switch on the front of the replaced IDU unit.
10) Wait a while to allow re-initialization of the unit. During this phase the LED on the front
Panel are blinking.
11) Connect a PC as a LCT to the LCT port on the IDU front panel. A “IDU not operational” is
raised because the IDU MAC Address is not correct.
12) Using the
System
Settings→Idu
Management window (par. 2.10) execute an automatic
upload of the IDU MAC Address.
If the procedure is successful the MAC Address will be displayed in the
IDU MAC Address
field. The MAC address can be checked reading the label on the IDU.