remote system because the system is not able to filter dangerous operations. Otherwise cutting
the radio link makes in this case the terminal unreachable and a manual local intervention in the
terminal to restore service becomes necessary.
2.5.
Setting Date and Time
During system installation it is required to set the date and time of the ODU in order to have valid
timestamps in the log files and performance files. The date and time can be set in two different
modes by using the “System Settings” menu (see par. 2.10), locked to the
Local PC time
NTP server:
in this case the user need to enter the IP address of an NTP (Network Time
Protocol) server and the ODU contacts the server to synchronize its clock with it.
Note:
The system doesn’t have a backup battery and therefore the date and time is lost every time the
system is restarted. To maintain time and date the ODU automatically attempts a re-synchronization with the
NTP server (if defined) every 30 minutes. Moreover an automatic re-synchronization with the NTP server is
executed when the system is restarted,
2.6.
Figure 2-3: CT screen functional areas
In Fig. 2.4 the main areas of the screen are defined.
1)
Browser Area.
Proprietary of the specific browser used by the customer. Includes the IP
address area where the IP address of the equipment is displayed. If more equipment have