Specific instructions for SW download in 1+1 HSB Systems.
The SW download has to be
executed only on ODU in Stand-by status. Therefore it is required to put the Protection Group in a
Forced status using the Protection window on the ODU Main with External Request set to:
Forced
if SW download has to be executed on the ODU Protection
Lockout
if SW download has to be executed on the ODU Main
2.17.2 Change Password
It allows the management of the password changing the current password when required. Clicking
on the link “Admin→Change Password” open the dedicated pop-up window as shown in Fig. 2.20.
It is required to enter:
1. the Username (Username has the default value “operator” which cannot be changed)
2. the old Password
3. the new Password
4. again the new Password in the “Repeat New Password” field
5. click on the button <Change> when all fields are properly set
After the operation is executed, the pop-up window closes automatically and the new Password is
active.