SOCIETA’ ITALIANA COSTRUZIONI ELETTRONICHE S.r.l.
VIA TAZIO NUVOLARI, n° 53 - 55061 CARRAIA - (LU)
W e b s i t e : w w w . s i c e t e l e c o m. i t
ISCRIZ. TRIBUNALE LUCCA N. 8661 - C.C.I.A.A. N. 103668
P. IVA 00871160461 - Tel. 0583 980787 - Fax 0583 981495
E - M a i l : i n f o @ s i c e t e l e c o m. i t
After the new MAC Address is acquired, the "IDU not operational" alarm disappears and
the IDU LEDs will stop blinking.
The alternative procedure of next point 12) can be used if the automatic upload does not work.
13) Alternative procedure to manually enter the IDU MAC Address. The IDU MAC Address
can be manually entered in the same
System
Settings→Idu
Management window
reading it from the IDU label.
Check through LEDs visual inspection and basic CT procedures that the system works
properly.
14) Take off the antistatic protection armlet
15)
If the IDU (PSE) is part of a Protection Group (1+1 HSB system) the
Forced
status of the
Protection Group has to be cancelled, acting on the ODU Main and restoring the original
configuration.
5.3.2
Replacing the PSM (only for PSE/W)
Whilst in the case of 1+0 configurations it is recommended to replace in any case the complete
IDU, in case of 1+1 configurations using PSE/W (in order to guarantee as far as possible service
continuity) it is recommended to replace only the PSM module of the failed PSE/W if it can be
recognized that there is some power failure.
Note:
during replacement of PSM, power is provided to both 1+1 systems by the other PSE/W.
To replace PSM the following procedure has to be followed.
1)
Take from the stock a spare unit with the same P/N of the unit to replace
2)
Wear the antistatic armlet and connect its termination to a grounded structure
3)
Turn off (position O) the power switch on the front of the PSM to be replaced
4)
Disconnect the power cable from the front panel
5)
Extract the PSM module from the PSE/W unscrewing the two screws on the front
6)
Insert the new PSM in the PSE/W and block the screws
7)
Reconnect the power cable on the front panel
8)
Turn ON (position I) the power switch on the front panel and check that the LED is ON