SOCIETA’ ITALIANA COSTRUZIONI ELETTRONICHE S.r.l.
VIA TAZIO NUVOLARI, n° 53 - 55061 CARRAIA - (LU)
W e b s i t e : w w w . s i c e t e l e c o m. i t
ISCRIZ. TRIBUNALE LUCCA N. 8661 - C.C.I.A.A. N. 103668
P. IVA 00871160461 - Tel. 0583 980787 - Fax 0583 981495
E - M a i l : i n f o @ s i c e t e l e c o m. i t
Figure 2-4: Main Window
2.7.1
Summary System Status
In the upper
Summary System Status
area the following info is displayed and continuously
refreshed every few seconds:
i.
7 LED:
used to display summary alarms and functionality of the system reporting the
status of the Local and Remote Ends of the radio link:
for the Local End
o
In Service
(Transmitter On)
o
Alm
(Major Alarm)
o
Warn
(Warning Information)
o
RDI
(Remote Defect Indicator)
o
Loop
(RF Loop enabled)
for the Remote End:
o
RemAlm
(Major Alarm)
o
RemWarn
(Warning information)
Date
field: reports (yyyy/mm/dd
hh:mm:sec
format) the system date and hour. The
System Date can be updated and/or aligned to a reference Date using the System
Settings menu.
Temperature:
indication of the current temperature of the ODU.