SOCIETA’ ITALIANA COSTRUZIONI ELETTRONICHE S.r.l.
VIA TAZIO NUVOLARI, n° 53 - 55061 CARRAIA - (LU)
W e b s i t e : w w w . s i c e t e l e c o m. i t
ISCRIZ. TRIBUNALE LUCCA N. 8661 - C.C.I.A.A. N. 103668
P. IVA 00871160461 - Tel. 0583 980787 - Fax 0583 981495
E - M a i l : i n f o @ s i c e t e l e c o m. i t
Three sets of counters are displayed in two window areas:
Current Counters
displayed in the
Current
area. These counters report the values related
to the current 15’ period. The current counters values are displayed when the window is
opened and can be updated by pressing the button <Update>.
15 minutes Historical Counters
displayed in the
Records
area by selecting the
15
minutes
tab. When the data collection is enabled, at the end of each 15min period the
current 15min counter:
o
is stored as new Interval with the its timestamp
o
is added to the current 24h counter
o
restarts counting
Counters related to the past collected 15min periods (Intervals) are displayed (one Interval
per line) up to a max of 96 periods (1 day).
24 hours Historical Counters
displayed in the
Records
area by selecting the
24 hours
tab When the data collection is enabled, the current (Interval = 0) 24h counter is
incremented at the end of each 15’ period. At the end of each 24h period the current
(Interval = 0) 24h counter.
o
Is stored as a new Interval
o
restarts counting.
Counters related to the past collected 24h periods (Intervals) are displayed (one Interval
per line) up to a max of 7 periods (1 week).
A number of command buttons in the top line of the window allow to manage the data collected by
the counters relevant to the selected
PM type.
<Reset>:
The <Reset> button clears simultaneously all the historical records
<Update>:
The window displays the current counters values and stored interval records
when the window is opened: they can all be refreshed by the operator by clicking on the
<Update>button.
<EnableDisable>: this button is relevant to the set of Historical Counters selected by the
active tab in the Records area. By clicking on the button the status is reversed
o
When Enabled (√) the counters are regularly incremented
o
When Disabled ( ) the counters are frozen at the last value
o
The transition from Disabled to Enabled clears the current record
<Export> : By pressing this button a dedicated pop-up window is opened (see Fig. 2.12)
and the set of Historical Counters selected by the active tab in the Records area can be
saved on the CT PC. The file is formatted with Comma Separated Values format which can
be opened by most known spreadsheets applications. The name of the file is:
Performances15min_<SysName>_<LocationName>_yyyy_mm_dd_hh.mm.ss.csv
or
Performances24h_<SysName>_<LocationName>_yyyy_mm_dd_hh.mm.ss.csv
Once the file has been downloaded, it can be processed opening the relevant application
on PC.