SOCIETA’ ITALIANA COSTRUZIONI ELETTRONICHE S.r.l.
VIA TAZIO NUVOLARI, n° 53 - 55061 CARRAIA - (LU)
W e b s i t e : w w w . s i c e t e l e c o m. i t
ISCRIZ. TRIBUNALE LUCCA N. 8661 - C.C.I.A.A. N. 103668
P. IVA 00871160461 - Tel. 0583 980787 - Fax 0583 981495
E - M a i l : i n f o @ s i c e t e l e c o m. i t
Table 2-4: Parameters displayed in the Radio Interface/Radio Info
b) Radio Configuration
The parameters defining the radio operation can be defined using the four functional areas:
Interface
Modem
Frequency
Power
In each of them it is possible to set and/or modify the relevant parameters as defined in Table 2.5.
Note that the new settings of each area will be executed only when the <Apply> button at the
bottom of each area is pressed.
The following specific remarks apply for
unlicensed bands:
It is possible to set independently Tx and Rx frequencies, within the limits displayed in the
Radio Info for each of them. Therefore a value can be entered by the operator also in the
RxFrequency
field of the
Frequency
area.
The
Tx-Rx Shift
shows as default the standard shift between the Tx and Rx frequencies
set in the system. If Tx or Rx frequencies are set differently by the operator
Tx-Rx Shift
shows the actual value (difference between the two frequencies). Note that the Radio Info
is not automatically refreshed, so that the new value is displayed only reopening the Radio
Interface window
The default operation (with Tx and Rx separated by the default Tx-Rx Shift) is the start up
condition and can be restored typing the value 0.00 in the
Rx Frequency
field and clicking
on <Apply>. After <Apply>,
Rx Frequency
will display the actual value corresponding to
the default Shifter.
a <Radio Frequency Seeker> button is added in the
Frequency
area to open the dedicated
tool described in the following par. 2.8.1